Catalogue / Transformer overhaul & oil filtration

No photo yet

Transformer oil filtration and dehydration, Xtra seriesSample

by Tungabhadra Engineering Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Tungabhadra Engineering Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Tungabhadra Xtra transformer oil filtration and dehydration, offered in 5 transformer rating options from 5 MVA to 100 MVA. Highlights: oil sampling and DGA before work, nitrogen or dry air purge on opening and leak testing before energisation. Typically used for captive power plants, solar and wind pooling substations and industrial distribution transformers. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Mobilisation in 3-5 days; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Tungabhadra
Model
TUN-796 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Mobilisation in 3-5 days
Warranty
Workmanship 12 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating5 MVATUN-796-01Transformer rating: 5 MVA1 nos · Mobilisation in 3-5 daysfor verified buyers
Transformer rating10 MVATUN-796-02Transformer rating: 10 MVA1 nos · Mobilisation in 3-5 daysfor verified buyers
Transformer rating20 MVATUN-796-03Transformer rating: 20 MVA1 nos · Mobilisation in 3-5 daysfor verified buyers
Transformer rating50 MVATUN-796-04Transformer rating: 50 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating100 MVATUN-796-05Transformer rating: 100 MVA1 nos · Planned shutdown requiredfor verified buyers

Specifications

Transformer rating5 MVA to 100 MVA (see variants)
ServiceInternal inspection and overhaul
Filtration machineMobile 12000 L/hrmade to order: Vacuum dehydration 6000 L/hr
Oil BDV targetAbove 60 kV
Moisture targetBelow 10 ppmmade to order: Below 5 ppm
TestingDGA, furan, BDV, tan delta
SparesBushings and OLTC parts at cost
Downtime2-3 days
Site workHot oil circulation at site
Crew4 technicians with supervisormade to order: Specialised overhaul team
CertificateOverhaul report with test datamade to order: Oil test report from NABL lab