Catalogue / Gas-insulated switchgear (GIS)

No photo yet

Gas-insulated switchgear 145 kV, Pro seriesSample

by Tungabhadra HV Switchgear (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Tungabhadra HV Switchgear (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Tungabhadra Pro gas-insulated switchgear 145 kV, offered in 5 system voltage options from 36 kV to 420 kV. Highlights: UHF partial discharge sensors, compact footprint, up to 90% saving and suitable for indoor and outdoor. Suited to offshore and hilly regions, industrial plants and urban substations. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 20-28 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Tungabhadra
Model
TUN-981 series
Listing type
Product
Unit
bay
Minimum order
10 bay
Lead time
20-28 weeks
Warranty
24 months
Standards
IEC 62271-203, IEC 62271-1, IEC 62271-100
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Packaging
Drum / reel with end caps
Delivery terms
Ex-works, freight extra at actuals
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
System voltage36 kVTUN-981-01System voltage: 36 kV10 bay · 20-28 weeksfor verified buyers
System voltage72.5 kVTUN-981-02System voltage: 72.5 kV10 bay · 20-28 weeksfor verified buyers
System voltage145 kVTUN-981-03System voltage: 145 kV10 bay · 20-28 weeksfor verified buyers
System voltage245 kVTUN-981-04System voltage: 245 kV10 bay · 40-52 weeksfor verified buyers
System voltage420 kVTUN-981-05System voltage: 420 kV10 bay · 40-52 weeksfor verified buyers

Specifications

System voltage36 kV to 420 kV (see variants)
Rated current4000 A
Short-circuit current40 kA
ConfigurationSingle bus
EnclosureAluminium alloy
GasSF6/N2 mix
Bay width800 mm
Operating mechanismMotormade to order: Spring
Partial discharge monitoringUHF sensors
ControlLocal control cubicle with BCU
Gas leakage< 0.1% per year
Earth switchesMaintenance + fast acting
InterlocksMechanical and electrical