Catalogue / SF6 circuit breakers

No photo yet

SF6 live tank circuit breaker, Plus 5 seriesSample

by Tungabhadra HV Switchgear (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Tungabhadra HV Switchgear (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Plus 5 range of SF6 live tank circuit breaker by Tungabhadra covers 5 system voltage options (36 kV to 420 kV). Key features: density monitor with two stage alarm, low SF6 leakage < 0.5% per year and type tested at KEMA or CPRI. Used by renewable pooling stations, transmission lines and industrial EHV supply. Designed and tested to IEC 62271-100, IS 13118 and IEC 62271-1. Lead time 24-30 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Tungabhadra
Model
TUN-786 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
24-30 weeks
Warranty
30 months from supply
Standards
IEC 62271-100, IS 13118, IEC 62271-1
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Wooden crate, seaworthy
Delivery terms
FOR nearest railhead
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
System voltage36 kVTUN-786-01System voltage: 36 kV1 nos · 24-30 weeksfor verified buyers
System voltage72.5 kVTUN-786-02System voltage: 72.5 kV1 nos · 24-30 weeksfor verified buyers
System voltage145 kVTUN-786-03System voltage: 145 kV1 nos · 24-30 weeksfor verified buyers
System voltage245 kVTUN-786-04System voltage: 245 kV1 nos · 24-30 weeksfor verified buyers
System voltage420 kVTUN-786-05System voltage: 420 kV1 nos · 24-30 weeksfor verified buyers

Specifications

System voltage36 kV to 420 kV (see variants)
Rated current1250 Amade to order: 2000 A / 3150 A / 4000 A
Breaking current50 kAmade to order: 25 kA / 31.5 kA / 40 kA
Operating mechanismHydraulic spring
OperationSingle-pole
InterrupterTwo breaks
SF6 pressure0.6 MPa abs
Duty cycleO-0.3s-CO-3min-CO
Close time< 60 msmade to order: < 100 ms
InsulatorPorcelain
Auxiliary supply220 V DCmade to order: 110 V DC
Creepage31 mm/kV
Mechanical enduranceM2

BARREL: Bharat Atom Renewable Resources Energy Limited