The Elite range of compact switching assembly by Tungabhadra covers 4 system voltage options (72.5 kV to 420 kV). Design: seismic qualified, reduced foundation and civil work and fewer SF6 joints. Suited to pollution and coastal areas, compact substations and seismic zones. Designed and tested to IEC 62271-100, IEC 62271-108 and IEC 62271-1. Lead time 16-24 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Tungabhadra
- Model
- TUN-CB5 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 16-24 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-100, IEC 62271-108, IEC 62271-1
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Door delivery in metro cities
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage72.5 kVTUN-CB5-01 | System voltage: 72.5 kV | 2 nos · 16-24 weeks | for verified buyers |
| System voltage145 kVTUN-CB5-02 | System voltage: 145 kV | 2 nos · 16-24 weeks | for verified buyers |
| System voltage245 kVTUN-CB5-03 | System voltage: 245 kV | 2 nos · 28-36 weeks | for verified buyers |
| System voltage420 kVTUN-CB5-04 | System voltage: 420 kV | 2 nos · 28-36 weeks | for verified buyers |
Specifications
| System voltage | 72.5 kV to 420 kV (see variants) |
|---|---|
| Concept | Compactmade to order: Dead tank / Hybrid |
| Rated current | 4000 Amade to order: 2000 A / 3150 A |
| Breaking current | 40 kA |
| Gas | SF6made to order: SF6-free |
| Integrated CT | Yes, up to 5 cores |
| Integrated disconnector | Yes |
| Integrated earth switch | Yes |
| Mechanism | Motor spring |
| Insulation | Air outdoor bushings |
| Footprint saving | 50-70% |
| Operating temp | -30 to 50 deg C |
| Monitoring | Gas density, operation counter |