Catalogue / Static VAR compensators (SVC)
Thyristor-controlled reactor SVC (TCR+FC), Max seriesSample
by Tungabhadrasamarth Drives & Controls (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Tungabhadrasamarth Drives & Controls (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Tungabhadrasamarth Max thyristor-controlled reactor SVC (TCR+FC), offered in 4 rating options from 5 MVAr to 40 MVAr. Key features: phase-wise independent control for unbalance, automatic filter switching and protection and supervisory SCADA integration. Typically used for grid voltage support at remote substations, traction substations and rolling mills. Designed and tested to IEC 61954, IEC 60871 and IEEE 1031. Lead time 30-40 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Tungabhadrasamarth
- Model
- TUN-713 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 30-40 weeks
- Warranty
- 24 months from commissioning
- Standards
- IEC 61954, IEC 60871, IEEE 1031
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating5 MVArTUN-713-01 | Rating: 5 MVAr | 1 nos · 30-40 weeks | on quote |
| Rating10 MVArTUN-713-02 | Rating: 10 MVAr | 1 nos · 30-40 weeks | on quote |
| Rating20 MVArTUN-713-03 | Rating: 20 MVAr | 1 nos · 30-40 weeks | on quote |
| Rating40 MVArTUN-713-04 | Rating: 40 MVAr | 1 nos · 30-40 weeks | on quote |
Specifications
| Rating | 5 MVAr to 40 MVAr (see variants) |
|---|---|
| System voltage | 11 kVmade to order: 33 kV / 66 kV / 132 kV |
| Configuration | TCR + FC |
| Thyristor valve | Water-cooledmade to order: Air-cooled |
| Response time | < 20 ms |
| Harmonic filters | 3rd, 5th, 7th, 11th |
| Control | Constant voltage, constant PF |
| Reactor | Dry-type air-core |
| Communication | IEC 60870-5-104made to order: IEC 61850 |
| Cooling | Deionised water-glycolmade to order: Forced air |
| Efficiency | > 99.2% |
| Operating range | Capacitive and inductive |