Floor-standing downflow precision AC, Smart seriesSample
by Ujjayini Data Centre Power (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Ujjayini Data Centre Power (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Smart range of floor-standing downflow precision AC by Ujjayini covers 3 cooling capacity options (35 kW to 80 kW). Highlights: lead-lag and standby unit rotation, EC fans modulate with rack inlet temperature and designed for continuous 24x7 operation. Used by telecom exchanges, laboratories and data centres. Designed and tested to ASHRAE TC 9.9, ISO 5151 and IS 1391 (Part 1). Lead time 4-6 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Ujjayini
- Model
- UJJ-9E9 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 4-6 weeks
- Warranty
- 24 months from supply
- Standards
- ASHRAE TC 9.9, ISO 5151, IS 1391 (Part 1)
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Cooling capacity35 kWUJJ-9E9-01 | Cooling capacity: 35 kW | 5 nos · 4-6 weeks | for verified buyers |
| Cooling capacity50 kWUJJ-9E9-02 | Cooling capacity: 50 kW | 5 nos · 4-6 weeks | for verified buyers |
| Cooling capacity80 kWUJJ-9E9-03 | Cooling capacity: 80 kW | 5 nos · 4-6 weeks | for verified buyers |
Specifications
| Cooling capacity | 35 kW to 80 kW (see variants) |
|---|---|
| Type | Chilled watermade to order: DX air-cooled / DX water-cooled |
| Airflow | In-rowmade to order: Downflow / Upflow |
| Compressor | Scrollmade to order: Inverter scroll / Not applicable |
| Fan | Backward-curved ECmade to order: EC plug fan |
| Sensible heat ratio | Above 0.9 |
| Humidification | Electrode steam |
| Dehumidification | Electric reheat |
| Control | Microprocessor with web interface |
| Supply | 415 V 3-phase 50 Hz |
| Refrigerant | R410A |
| Condenser | Remote air-cooledmade to order: Integral |
| Filtration | G4made to order: F5 |