Catalogue / Substation automation (IEC 61850)

No photo yet

Station SCADA with redundant servers, Max 3 seriesSample

by Ujjayinisetu Protection Systems (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Ujjayinisetu Protection Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Max 3 range of station SCADA with redundant servers by Ujjayinisetu covers 5 bays options (Up to 8 bays to Up to 128 bays). Design: cyber-secure remote access, interoperable multi-vendor bay devices and sequence of events recorder. Suited to solar pooling stations, discom 33/11 kV substations and metro traction. Designed and tested to IEC 61850, IEC 62351 and IEC 60870-5-104. Lead time 16-24 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Ujjayinisetu
Model
UJJ-353 series
Listing type
Product
Unit
lot
Minimum order
1 lot
Lead time
16-24 weeks
Warranty
24 months
Standards
IEC 61850, IEC 62351, IEC 60870-5-104
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
Door delivery in metro cities
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
BaysUp to 8 baysUJJ-353-01Bays: Up to 8 bays1 lot · 16-24 weeksfor verified buyers
BaysUp to 16 baysUJJ-353-02Bays: Up to 16 bays1 lot · 16-24 weeksfor verified buyers
BaysUp to 32 baysUJJ-353-03Bays: Up to 32 bays1 lot · 16-24 weeksfor verified buyers
BaysUp to 64 baysUJJ-353-04Bays: Up to 64 bays1 lot · 16-24 weeksfor verified buyers
BaysUp to 128 baysUJJ-353-05Bays: Up to 128 bays1 lot · 16-24 weeksfor verified buyers

Specifications

BaysUp to 8 bays to Up to 128 bays (see variants)
ArchitectureStation busmade to order: Station + process bus
ProtocolDNP3made to order: IEC 61850 Ed 2 / IEC 60870-5-104
Network topologyPRPmade to order: Dual star / HSR ring
HMISingle HMImade to order: Redundant servers
Time syncGPS with PTPmade to order: SNTP
GatewayRedundant to RLDC / SLDC
Cyber-securityFirewall, IEC 62351, NERC style
HistorianIncluded, 5 years data
Engineering toolConfiguration software
Network switchesIndustrial managed
Auxiliary supply220 V DC
TestingFAT + SAT

BARREL: Bharat Atom Renewable Resources Energy Limited