Catalogue / Surge arresters (station class)
Station class metal oxide surge arrester, Max seriesSample
by Ujjayini Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Ujjayini Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Max range of station class metal oxide surge arrester by Ujjayini covers 6 system voltage options (12 kV to 420 kV). Highlights: surge counter with leakage current meter, gapless zinc oxide blocks and light weight, vandal proof. Typically used for transformer protection, railway traction and solar plants. Designed and tested to IEC 60099-4, IS 3070 (Part 3) and IEC 60099-5. Lead time 3-5 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Ujjayini
- Model
- UJJ-FF8 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 3-5 weeks
- Warranty
- 36 months
- Standards
- IEC 60099-4, IS 3070 (Part 3), IEC 60099-5
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- Door delivery in metro cities
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage12 kVUJJ-FF8-01 | System voltage: 12 kV | 2 nos · 3-5 weeks | for verified buyers |
| System voltage36 kVUJJ-FF8-02 | System voltage: 36 kV | 2 nos · 3-5 weeks | for verified buyers |
| System voltage72.5 kVUJJ-FF8-03 | System voltage: 72.5 kV | 2 nos · 3-5 weeks | for verified buyers |
| System voltage145 kVUJJ-FF8-04 | System voltage: 145 kV | 2 nos · 3-5 weeks | for verified buyers |
| System voltage245 kVUJJ-FF8-05 | System voltage: 245 kV | 2 nos · 8-10 weeks | for verified buyers |
| System voltage420 kVUJJ-FF8-06 | System voltage: 420 kV | 2 nos · 8-10 weeks | for verified buyers |
Specifications
| System voltage | 12 kV to 420 kV (see variants) |
|---|---|
| Rated voltage | 9 kVmade to order: 30 kV / 120 kV / 192 kV |
| Nominal discharge current | 5 kA |
| Line discharge class | Class 4made to order: Class 2 / Class 3 / Class 5 |
| Housing | Porcelainmade to order: Polymer |
| Pressure relief class | 63 kA |
| Creepage | 25 mm/kV |
| Energy capability | 7 kJ/kV |
| Counter | With leakage current indicator |
| Mounting | Pedestalmade to order: Line |
| Base insulator | Included |
| Disconnector | Optional |
| Ambient | -40 to 60 deg C |