Catalogue / Electrical safety audits
Earthing and lightning protection audit, Neo 4 seriesSample
by Urjatek Projects (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Urjatek Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Neo 4 service of earthing and lightning protection audit by Urjatek covers 5 installed load options (1 MVA to 50 MVA). Design: risk-ranked findings, compliance matrix against CEA safety rules and earthing health and soil resistivity. Suited to manufacturing plants, hospitals and commercial buildings and solar and wind sites. Delivered in line with Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations and IS 5216. Mobilisation Audit in 1-2 weeks; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Urjatek
- Model
- URJ-5F2 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Audit in 1-2 weeks
- Warranty
- Clarifications on report at no cost for 6 months
- Standards
- Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations, IS 5216
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Installed load1 MVAURJ-5F2-01 | Installed load: 1 MVA | 1 site · Audit in 1-2 weeks | for verified buyers |
| Installed load5 MVAURJ-5F2-02 | Installed load: 5 MVA | 1 site · Audit in 1-2 weeks | for verified buyers |
| Installed load10 MVAURJ-5F2-03 | Installed load: 10 MVA | 1 site · Audit in 1-2 weeks | for verified buyers |
| Installed load25 MVAURJ-5F2-04 | Installed load: 25 MVA | 1 site · Report in 7-14 days | for verified buyers |
| Installed load50 MVAURJ-5F2-05 | Installed load: 50 MVA | 1 site · Report in 7-14 days | for verified buyers |
Specifications
| Installed load | 1 MVA to 50 MVA (see variants) |
|---|---|
| Scope | Audit with measurements |
| Auditor | CEA-licensed engineermade to order: Chartered engineer |
| Measurements | Thermography and power qualitymade to order: Earth resistance, insulation |
| Report | Action plan with timeline |
| Statutory records | Registers, test certificates, licence |
| Sampling | Representative LV panels |
| Follow-up | Close-out verificationmade to order: Re-audit after 3 months |
| Turnaround | 1-2 weeksmade to order: 3-4 weeks |
| Presentation | Findings to management |
| Accreditation | ISO/IEC 17020 body |