Catalogue / BMS & energy management (EMS)
Rack-level BMS master and slave units, Titan seriesSample
by Vaigaidhruv Battery Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Vaigaidhruv Battery Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Titan range of rack-level BMS master and slave units by Vaigaidhruv covers 3 system scale options (Up to 100 kWh to Up to 2 MWh). Key features: OPC UA gateway for plant SCADA, cell-to-cloud monitoring with alarms and event and fault recorder with time stamps. Suited to telecom and data-centre backup, microgrid controllers and c&I behind-the-meter storage. Designed and tested to IEC 62619, IEC 61850 and IEC 62443. Lead time 3-5 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Vaigaidhruv
- Model
- VAI-E03 series
- Listing type
- Product
- Unit
- set
- Minimum order
- 1 set
- Lead time
- 3-5 weeks
- Warranty
- 24 months from supply
- Standards
- IEC 62619, IEC 61850, IEC 62443
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System scaleUp to 100 kWhVAI-E03-01 | System scale: Up to 100 kWh | 1 set · 3-5 weeks | for verified buyers |
| System scaleUp to 500 kWhVAI-E03-02 | System scale: Up to 500 kWh | 1 set · 3-5 weeks | for verified buyers |
| System scaleUp to 2 MWhVAI-E03-03 | System scale: Up to 2 MWh | 1 set · 3-5 weeks | for verified buyers |
Specifications
| System scale | Up to 100 kWh to Up to 2 MWh (see variants) |
|---|---|
| Cell count supported | Up to 192 series |
| Voltage sensing accuracy | +/- 5 mV |
| Temperature sensing | NTC, +/- 1 deg C |
| SOC accuracy | +/- 3% |
| Balancing | Passive 100 mAmade to order: Active 1 A |
| Protocols | Modbus TCPmade to order: IEC 61850 / IEC 60870-5-104 / DNP3 |
| Dispatch modes | Arbitrage |
| Data logging | 1 s resolution |
| Cloud interface | MQTT |
| Cyber-security | Role-based access, TLS 1.2 |
| Hardware | Industrial PC |
| Redundancy | Hot-standby controller |