Catalogue / PLC & DCS

No photo yet

Redundant PLC for process control, Max 5 seriesSample

by Vidarbhalumen Instruments (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vidarbhalumen Instruments (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Max 5 range of redundant PLC for process control by Vidarbhalumen covers 6 i/O points options (64 I/O to 2048 I/O). Highlights: programming with standard IEC 61131-3 languages, integrated safety (SIL 2/3) option and firmware with cyber-security hardening. Typically used for boiler and turbine auxiliaries, water treatment and utilities and substation and process automation. Designed and tested to IEC 61131-2, IEC 61131-3 and IEC 61508 (SIL 2/3). Lead time 4-6 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vidarbhalumen
Model
VID-069 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
4-6 weeks
Warranty
12 months from commissioning
Standards
IEC 61131-2, IEC 61131-3, IEC 61508 (SIL 2/3)
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
FOR nearest railhead
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
I/O points64 I/OVID-069-01I/O points: 64 I/O1 nos · 4-6 weekson quote
I/O points128 I/OVID-069-02I/O points: 128 I/O1 nos · 4-6 weekson quote
I/O points256 I/OVID-069-03I/O points: 256 I/O1 nos · 4-6 weekson quote
I/O points512 I/OVID-069-04I/O points: 512 I/O1 nos · 4-6 weekson quote
I/O points1024 I/OVID-069-05I/O points: 1024 I/O1 nos · 8-12 weekson quote
I/O points2048 I/OVID-069-06I/O points: 2048 I/O1 nos · 8-12 weekson quote

Specifications

I/O points64 I/O to 2048 I/O (see variants)
CPU memory8 MBmade to order: 512 KB / 2 MB
Scan time< 0.1 ms per 1k
RedundancyHot standby CPU and networkmade to order: None
ProgrammingIEC 61131-3 (LD, FBD, ST)
CommunicationProfibus DP
Digital input24 VDC sink/source
Analog input4-20 mA HARTmade to order: RTD/TC
Power supply110-230 VACmade to order: 24 VDC
Operating temperature0 to 60 °C
Hot swapYes, I/O modules
SecurityPassword + access control, firmware signing