Catalogue / Thermography & condition monitoring
Drone thermal inspection of solar plants, Smart 4 seriesSample
by Vidarbha Projects (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Vidarbha Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Vidarbha Smart 4 drone thermal inspection of solar plants, offered in 3 asset size options from 1 MW to 10 MW. Design: priority list of defects with repair advice, safe scanning without shutdown and hotspot location tagged with GPS. Typically used for wind turbine electrical systems, substation switchgear and transformers and solar plants (module and string hotspots). Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Report in 5-10 days; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Vidarbha
- Model
- VID-F99 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Report in 5-10 days
- Warranty
- Report accuracy as per method
- Standards
- ISO 18434-1, IEC 62446-3, IEEE 1584
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Asset size1 MWVID-F99-01 | Asset size: 1 MW | 1 site · Report in 5-10 days | on quote |
| Asset size5 MWVID-F99-02 | Asset size: 5 MW | 1 site · Report in 5-10 days | on quote |
| Asset size10 MWVID-F99-03 | Asset size: 10 MW | 1 site · Report in 5-10 days | on quote |
Specifications
| Asset size | 1 MW to 10 MW (see variants) |
|---|---|
| Technique | Partial discharge testing |
| Camera resolution | 1280x1024 radiometricmade to order: 640x480 radiometric |
| Deliverable | Annotated hotspot reportmade to order: CAT-wise severity ranking with fix actions |
| Drone services | Orthomosaic of full plantmade to order: Ground sampling 3 cm per pixel |
| Defect classification | Per client maintenance policy |
| Team | Level II thermographer |
| Certification | Technicians with ASNT level IImade to order: ISO 18436-7 trained |
| Turnaround | Report in 10 daysmade to order: Report in 5 days |
| Frequency | One-time |
| Software | Cloud dashboard with trend historymade to order: Analyser software with thermal library |