Power transformer overhaul and oil reconditioning, Plus seriesSample

by Vidarbha Projects (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vidarbha Projects (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Plus service of power transformer overhaul and oil reconditioning by Vidarbha covers 5 transformer rating options (1 MVA to 50 MVA). Key features: leak testing before energisation, nitrogen or dry air purge on opening and oil sampling and DGA before work. Suited to industrial distribution transformers, solar and wind pooling substations and state utility asset life extension. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vidarbha
Model
VID-4C6 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Planned shutdown required
Warranty
Oil quality guarantee 6 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating1 MVAVID-4C6-01Transformer rating: 1 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating5 MVAVID-4C6-02Transformer rating: 5 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating10 MVAVID-4C6-03Transformer rating: 10 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating20 MVAVID-4C6-04Transformer rating: 20 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating50 MVAVID-4C6-05Transformer rating: 50 MVA1 nos · Planned shutdown requiredfor verified buyers

Specifications

Transformer rating1 MVA to 50 MVA (see variants)
ServiceInternal inspection and overhaulmade to order: Oil filtration and dehydration / Oil reclamation / Full overhaul with rewinding
Filtration machineMobile 12000 L/hrmade to order: Vacuum dehydration 6000 L/hr
Oil BDV targetAbove 60 kV
Moisture targetBelow 10 ppmmade to order: Below 5 ppm
TestingFull routine tests after overhaul
SparesGaskets and silica gelmade to order: Bushings and OLTC parts at cost
Downtime3-4 weeks
Site workHot oil circulation at sitemade to order: Workshop repair
Crew4 technicians with supervisor
CertificateOil test report from NABL lab