Catalogue / Lightning arresters (ESE, conventional)

No photo yet

Lightning mast with ESE terminal, Prime seriesSample

by Vidyutmax Earthing Systems (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vidyutmax Earthing Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Prime range of lightning mast with ESE terminal by Vidyutmax covers 5 protection radius (Level III) options (35 m to 85 m). Design: lightning event counter fitted at down conductor, stainless steel construction against corrosion and tested advance time at accredited laboratory. Typically used for telecom towers and control rooms, industrial buildings and storage tanks and substations and switchyards. Designed and tested to IS/IEC 62305, NF C 17-102 and IS 2309. Lead time 4-6 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vidyutmax
Model
VID-0E9 series
Listing type
Product
Unit
nos
Minimum order
10 nos
Lead time
4-6 weeks
Warranty
10 years
Standards
IS/IEC 62305, NF C 17-102, IS 2309
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
Door delivery in metro cities
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Protection radius (Level III)35 mVID-0E9-01Protection radius (Level III): 35 m10 nos · 4-6 weekson quote
Protection radius (Level III)45 mVID-0E9-02Protection radius (Level III): 45 m10 nos · 4-6 weekson quote
Protection radius (Level III)55 mVID-0E9-03Protection radius (Level III): 55 m10 nos · 4-6 weekson quote
Protection radius (Level III)65 mVID-0E9-04Protection radius (Level III): 65 m10 nos · 4-6 weekson quote
Protection radius (Level III)85 mVID-0E9-05Protection radius (Level III): 85 m10 nos · 4-6 weekson quote

Specifications

Protection radius (Level III)35 m to 85 m (see variants)
TypeFranklin rod
Advance time60 µsmade to order: 15 µs / 30 µs / 45 µs
MaterialCopper
Mast3 m GI pole
Down conductor50 mm² coppermade to order: 25x3 mm GI strip
CounterLightning event counter
Test certificateLaboratory tested to NF C 17-102
Ingress protectionIP67
MountingRoof
Warranty10 years
Protection levelLevel Imade to order: Level II / Level III

BARREL: Bharat Atom Renewable Resources Energy Limited