Catalogue / Power system studies (load flow, short circuit, grid code)

No photo yet

Protection coordination and relay setting, Eco 5 seriesSample

by Vidyuttron Engineering Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vidyuttron Engineering Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Eco 5 service of protection coordination and relay setting by Vidyuttron covers 5 network scale options (11 kV plant to 220 kV system). Key features: models acceptable to STU and CTUIL, fault level verification of switchgear and reports for GNA/connectivity application. Typically used for utilities and consultants, BESS integrators and industrial plants adding generation. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation Kick-off in 1 week; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vidyuttron
Model
VID-F11 series
Listing type
Service
Unit
report
Minimum order
1 report
Lead time
Kick-off in 1 week
Warranty
Clarifications to utility at no cost
Standards
CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Network scale11 kV plantVID-F11-01Network scale: 11 kV plant1 report · Kick-off in 1 weekfor verified buyers
Network scale33 kV plantVID-F11-02Network scale: 33 kV plant1 report · Kick-off in 1 weekfor verified buyers
Network scale66 kV systemVID-F11-03Network scale: 66 kV system1 report · Kick-off in 1 weekfor verified buyers
Network scale132 kV systemVID-F11-04Network scale: 132 kV system1 report · 2-6 weeksfor verified buyers
Network scale220 kV systemVID-F11-05Network scale: 220 kV system1 report · 2-6 weeksfor verified buyers

Specifications

Network scale11 kV plant to 220 kV system (see variants)
Study typeHarmonics
SoftwarePSS/Emade to order: ETAP / DIgSILENT PowerFactory
Model dataClient single line diagram and data
DeliverablesModel files and relay settings
Grid code checksVoltage and reactive power capabilitymade to order: LVRT/HVRT and ramp rate
ReviewLender review
ScenariosNormal and N-1
TeamLead plus modelling specialistmade to order: Power system engineer
Turnaround2-3 weeks
ValidationCompared with measured datamade to order: Peer review

BARREL: Bharat Atom Renewable Resources Energy Limited