Catalogue / Gas-insulated switchgear (GIS)
Gas-insulated switchgear 145 kV, Max 6 seriesSample
by Vijaya Grid Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Vijaya Grid Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Gas-insulated switchgear 145 kV from Vijaya, Max 6 series: 5 system voltage options between 36 kV and 420 kV. Highlights: suitable for indoor and outdoor, compact footprint, up to 90% saving and maintenance-free enclosed design. Suited to industrial plants, urban substations and renewable pooling stations. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Vijaya
- Model
- VIJ-985 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- 40-52 weeks
- Warranty
- 24 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVVIJ-985-01 | System voltage: 36 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage72.5 kVVIJ-985-02 | System voltage: 72.5 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage145 kVVIJ-985-03 | System voltage: 145 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVVIJ-985-04 | System voltage: 245 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVVIJ-985-05 | System voltage: 420 kV | 1 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 420 kV (see variants) |
|---|---|
| Rated current | 3150 A |
| Short-circuit current | 40 kAmade to order: 31.5 kA / 50 kA |
| Configuration | Ring busmade to order: Single bus / Double bus |
| Enclosure | Steel |
| Gas | SF6/N2 mix |
| Bay width | 2500 mmmade to order: 800 mm / 1200 mm |
| Operating mechanism | Motor |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |