Catalogue / Gas-insulated switchgear (GIS)

No photo yet

Gas-insulated switchgear 145 kV, Duo 9 seriesSample

by Vijaya Grid Switchgear (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vijaya Grid Switchgear (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Gas-insulated switchgear 145 kV from Vijaya, Duo 9 series: 5 system voltage options between 36 kV and 420 kV. Key features: gas compartment with density monitors, UHF partial discharge sensors and compact footprint, up to 90% saving. Typically used for metro rail traction, industrial plants and urban substations. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vijaya
Model
VIJ-981 series
Listing type
Product
Unit
bay
Minimum order
1 bay
Lead time
40-52 weeks
Warranty
24 months
Standards
IEC 62271-203, IEC 62271-1, IEC 62271-100
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
FOR site, freight included
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
System voltage36 kVVIJ-981-01System voltage: 36 kV1 bay · 40-52 weeksfor verified buyers
System voltage72.5 kVVIJ-981-02System voltage: 72.5 kV1 bay · 40-52 weeksfor verified buyers
System voltage145 kVVIJ-981-03System voltage: 145 kV1 bay · 40-52 weeksfor verified buyers
System voltage245 kVVIJ-981-04System voltage: 245 kV1 bay · 40-52 weeksfor verified buyers
System voltage420 kVVIJ-981-05System voltage: 420 kV1 bay · 40-52 weeksfor verified buyers

Specifications

System voltage36 kV to 420 kV (see variants)
Rated current3150 Amade to order: 1250 A / 2500 A / 4000 A
Short-circuit current31.5 kAmade to order: 40 kA / 50 kA
ConfigurationSingle busmade to order: Double bus / Ring bus
EnclosureSteelmade to order: Aluminium alloy
GasSF6made to order: SF6/N2 mix / Clean air
Bay width800 mm
Operating mechanismMotormade to order: Spring
Partial discharge monitoringUHF sensors
ControlLocal control cubicle with BCU
Gas leakage< 0.1% per year
Earth switchesMaintenance + fast acting
InterlocksMechanical and electrical

BARREL: Bharat Atom Renewable Resources Energy Limited