Catalogue / Fire detection & alarm
Manual call point (MCP) and hooter, Edge 2 seriesSample
by Vindhya Fire Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Vindhya Fire Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Edge 2 range of manual call point (MCP) and hooter by Vindhya covers 3 panel loops / zones options (8 zones conventional to 2 loop addressable). Design: connect to BMS and SCADA, cause-and-effect programming and walk-test mode for commissioning. Typically used for battery rooms and BESS containers, offices and warehouses and control rooms and relay panel rooms. Designed and tested to IS 2189, EN 54-2 and EN 54-4. Lead time 4-6 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Vindhya
- Model
- VIN-236 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 4-6 weeks
- Warranty
- 24 months from supply
- Standards
- IS 2189, EN 54-2, EN 54-4
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Panel loops / zones8 zones conventionalVIN-236-01 | Panel loops / zones: 8 zones conventional | 1 nos · 4-6 weeks | for verified buyers |
| Panel loops / zones1 loop addressable (250 pts)VIN-236-02 | Panel loops / zones: 1 loop addressable (250 pts) | 1 nos · 4-6 weeks | for verified buyers |
| Panel loops / zones2 loop addressableVIN-236-03 | Panel loops / zones: 2 loop addressable | 1 nos · 4-6 weeks | for verified buyers |
Specifications
| Panel loops / zones | 8 zones conventional to 2 loop addressable (see variants) |
|---|---|
| Panel type | Conventionalmade to order: Addressable (analogue) |
| Loop capacity | 127 devicesmade to order: 250 devices per loop |
| Display | Alphanumeric LCDmade to order: Graphic touch |
| Network | Up to 32 panels |
| Power supply | 230 VAC with 24 V battery backup |
| Battery backup | 24 h standby + 30 min alarm |
| Outputs | Sounder circuits, relay outputs |
| Communication | RS-485made to order: Ethernet / Modbus to BMS |
| Enclosure | IP54 |
| Detector types | Multi-sensormade to order: Smoke / Heat / Beam |
| Event log | 10,000 events |