Catalogue / Transformer NIFPS

No photo yet

Transformer fire protection with explosion vent, Ultra 8 seriesSample

by Vindhya Fire Systems (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vindhya Fire Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Vindhya Ultra 8 transformer fire protection with explosion vent, offered in 6 transformer oil volume options from Up to 10 kL to Above 100 kL. Design: no water or foam damage to nearby equipment, rapid oil drain depressurises tank and fully automatic with manual override. Typically used for generator transformers at plants, renewable plant pooling transformers and power transformers at substations. Designed and tested to IS 3034, CBIP Manual on Transformers and CEA Safety Regulations 2023. Lead time 12-16 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vindhya
Model
VIN-3F2 series
Listing type
Product
Unit
set
Minimum order
1 set
Lead time
12-16 weeks
Warranty
36 months from commissioning
Standards
IS 3034, CBIP Manual on Transformers, CEA Safety Regulations 2023
Delivers to
North India
GST rate
18 %
Country of origin
India
Packaging
Wooden crate, seaworthy
Delivery terms
Ex-works, freight extra at actuals
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer oil volumeUp to 10 kLVIN-3F2-01Transformer oil volume: Up to 10 kL1 set · 12-16 weekson quote
Transformer oil volume10-20 kLVIN-3F2-02Transformer oil volume: 10-20 kL1 set · 12-16 weekson quote
Transformer oil volume20-40 kLVIN-3F2-03Transformer oil volume: 20-40 kL1 set · 12-16 weekson quote
Transformer oil volume40-60 kLVIN-3F2-04Transformer oil volume: 40-60 kL1 set · 12-16 weekson quote
Transformer oil volume60-100 kLVIN-3F2-05Transformer oil volume: 60-100 kL1 set · 12-16 weekson quote
Transformer oil volumeAbove 100 kLVIN-3F2-06Transformer oil volume: Above 100 kL1 set · 12-16 weekson quote

Specifications

Transformer oil volumeUp to 10 kL to Above 100 kL (see variants)
PrincipleDrain and stir
Nitrogen cylinders8 x 68 L
Operating pressure150 bar
Oil drain valvePneumatic
DetectionDifferential relay + Buchholz + heat detector
ControlPLC-based cubicle with hot standby
Response timeWithin 30 seconds
Oil drain depthTop 10% of the tank oil
Power supply110 VDCmade to order: 24 VDC with backup battery
Ex-ventIncluded
CommunicationHardwired to SCADAmade to order: IEC 60870-5-104
IsolationCable gland and cubicle IP55

BARREL: Bharat Atom Renewable Resources Energy Limited