Catalogue / Impressed-current & sacrificial-anode CP
Transformer rectifier unit, Pro seriesSample
by Wattsys Corrosion Engineers (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Wattsys Corrosion Engineers (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Pro range of transformer rectifier unit by Wattsys covers 6 TR unit rating options (12 V 10 A to 100 V 100 A). Highlights: automatic potential control option, meets pipeline protection criteria and test posts at intervals. Typically used for earthing grids, buried steel pipelines and tank bottoms and storage. Designed and tested to IS 8062, NACE SP0169 and ISO 15589-1. Lead time 3-4 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Wattsys
- Model
- WAT-C39 series
- Listing type
- Product
- Unit
- set
- Minimum order
- 10 set
- Lead time
- 3-4 weeks
- Warranty
- 12 months from commissioning
- Standards
- IS 8062, NACE SP0169, ISO 15589-1
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| TR unit rating12 V 10 AWAT-C39-01 | TR unit rating: 12 V 10 A | 10 set · 3-4 weeks | for verified buyers |
| TR unit rating24 V 20 AWAT-C39-02 | TR unit rating: 24 V 20 A | 10 set · 3-4 weeks | for verified buyers |
| TR unit rating50 V 25 AWAT-C39-03 | TR unit rating: 50 V 25 A | 10 set · 3-4 weeks | for verified buyers |
| TR unit rating50 V 50 AWAT-C39-04 | TR unit rating: 50 V 50 A | 10 set · 3-4 weeks | for verified buyers |
| TR unit rating50 V 100 AWAT-C39-05 | TR unit rating: 50 V 100 A | 10 set · 6-8 weeks | for verified buyers |
| TR unit rating100 V 100 AWAT-C39-06 | TR unit rating: 100 V 100 A | 10 set · 6-8 weeks | for verified buyers |
Specifications
| TR unit rating | 12 V 10 A to 100 V 100 A (see variants) |
|---|---|
| System type | Galvanicmade to order: ICCP |
| Anode material | Magnesium 17 lbmade to order: HSCI / MMO titanium / Zinc 20 lb |
| Cooling | Air cooledmade to order: Oil cooled |
| Output | Constant current |
| Input | 415 V 3 phasemade to order: 230 V single phase |
| Enclosure | IP 65 hazardous area |
| Reference electrode | Cu-CuSO4 |
| Monitoring | Remote monitoring unit |
| Test station | With coupon |