Air-insulated busduct for transformer connection, Duo seriesSample
by Wayanadvajra Panels (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Wayanadvajra Panels (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Duo range of air-insulated busduct for transformer connection by Wayanadvajra covers 5 rating options (1000 A to 4000 A). Design: compact low-impedance design with low voltage drop, joint packs with torque-controlled bolts and bends, tees, flanged ends and reducers available. Typically used for high-rise buildings, transformer to PCC links and industrial plant power distribution. Designed and tested to IEC 61439-6, IS 8623 (Part 2) and IEC 61439-1. Lead time 8-10 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Wayanadvajra
- Model
- WAY-336 series
- Listing type
- Product
- Unit
- m
- Minimum order
- 5 m
- Lead time
- 8-10 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 61439-6, IS 8623 (Part 2), IEC 61439-1
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating1000 AWAY-336-01 | Rating: 1000 A | 5 m · 8-10 weeks | for verified buyers |
| Rating1600 AWAY-336-02 | Rating: 1600 A | 5 m · 8-10 weeks | for verified buyers |
| Rating2500 AWAY-336-03 | Rating: 2500 A | 5 m · 8-10 weeks | for verified buyers |
| Rating3200 AWAY-336-04 | Rating: 3200 A | 5 m · 8-10 weeks | for verified buyers |
| Rating4000 AWAY-336-05 | Rating: 4000 A | 5 m · 8-10 weeks | for verified buyers |
Specifications
| Rating | 1000 A to 4000 A (see variants) |
|---|---|
| Conductor | Coppermade to order: Aluminium / Tinned copper |
| Rated voltage | 1000 Vmade to order: 415 V / 690 V |
| Construction | Sandwich type |
| Short-circuit withstand | 100 kA/1 s |
| Degree of protection | IP54 |
| Neutral | 100% neutral |
| Insulation | Class F polyestermade to order: Class B epoxy / PVC sleeved |
| Enclosure | Aluminium extrusion |
| Tap-off | Fixed bolt-on |
| Fire barrier | Provided at floor crossing |
| Expansion units | Not required |
| Phases | 3P4W |