Catalogue / Ring main units (RMU)
Extensible ring main unit with VCB, Max seriesSample
by Wayanadvajra Panels (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Wayanadvajra Panels (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Extensible ring main unit with VCB from Wayanadvajra, Max series: 3 configuration options between 3-way (LBS+LBS+VCB) and 4-way (3LBS+TF). Key features: cable test facility on front panel, three-position switch prevents closing onto earth and compact footprint for kiosk or indoor installation. Typically used for residential and commercial campuses, urban 11 kV ring networks and metro and airport distribution. Designed and tested to IEC 62271-200, IEC 62271-103 and IEC 62271-105. Lead time 4-6 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Wayanadvajra
- Model
- WAY-5C7 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 62271-200, IEC 62271-103, IEC 62271-105
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Configuration3-way (LBS+LBS+VCB)WAY-5C7-01 | Configuration: 3-way (LBS+LBS+VCB) | 5 nos · 4-6 weeks | for verified buyers |
| Configuration4-way (2LBS+LBS+VCB)WAY-5C7-02 | Configuration: 4-way (2LBS+LBS+VCB) | 5 nos · 4-6 weeks | for verified buyers |
| Configuration4-way (3LBS+TF)WAY-5C7-03 | Configuration: 4-way (3LBS+TF) | 5 nos · 4-6 weeks | for verified buyers |
Specifications
| Configuration | 3-way (LBS+LBS+VCB) to 4-way (3LBS+TF) (see variants) |
|---|---|
| Rated voltage | 36 kV |
| Rated current - ring | 630 A |
| Transformer feeder | 200 A fuse-switch |
| Short-circuit rating | 16 kA/3 s |
| Insulation medium | Solid dielectricmade to order: SF6 gas / Air insulated |
| Switch type | Disconnector + earthingmade to order: Three-position load-break |
| Extensibility | Extensible both sides |
| Protection relay | Self-powered O/C-E/F relay |
| Fault passage indicator | Optionalmade to order: Included |
| Enclosure | Stainless steel gas tankmade to order: Mild steel RAL 7035 |
| Degree of protection | IP54 |
| Motor operator | Not fittedmade to order: Optional on ring switches |