Gas-based suppressionRajatgen5 variants
SampleGas-based suppression Rajatgen · RAJ-4F9 series
- Protected volume
- Up to 50 m³ to 1000-3000 m³ (see variants)
- Agent
- HFC-227ea
- Cylinder pressure
- 42 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 12 months from commissioning · MOQ 1 set
Gas-based suppressionBrahmaputra4 variants
SampleGas-based suppression Brahmaputra · BRA-CC1 series
- Protected volume
- 50-150 m³ to 1000-3000 m³ (see variants)
- Agent
- IG-541
- Cylinder pressure
- 25 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 24 months from supply · MOQ 1 set
Gas-based suppressionVayumark5 variants
SampleGas-based suppression Vayumark · VAY-FA3 series
- Protected volume
- Up to 50 m³ to 1000-3000 m³ (see variants)
- Agent
- IG-541
- Cylinder pressure
- 42 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 24 months from supply · MOQ 1 set
Gas-based suppressionKavachcore4 variants
SampleGas-based suppression Kavachcore · KAV-616 series
- Protected volume
- Up to 50 m³ to 400-1000 m³ (see variants)
- Agent
- CO2
- Cylinder pressure
- 42 bar
- Discharge time
- 60 seconds (inert gas)
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 24 months from supply · MOQ 2 set
Gas-based suppressionAravalijal4 variants
SampleGas-based suppression Aravalijal · ARA-618 series
- Protected volume
- Up to 50 m³ to 400-1000 m³ (see variants)
- Agent
- IG-541
- Cylinder pressure
- 300 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 24 months from supply · MOQ 1 set
Gas-based suppressionBetwa5 variants
SampleGas-based suppression Betwa · BET-FA9 series
- Protected volume
- Up to 50 m³ to 1000-3000 m³ (see variants)
- Agent
- FK-5-1-12
- Cylinder pressure
- 300 bar
- Discharge time
- 60 seconds (inert gas)
- Detection
- Cross-zoned smoke detectors
Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 1 set
Gas-based suppressionBeas4 variants
SampleGas-based suppression Beas · BEA-CC1 series
- Protected volume
- Up to 50 m³ to 400-1000 m³ (see variants)
- Agent
- CO2
- Cylinder pressure
- 42 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 2 set
Gas-based suppressionVindhya4 variants
SampleGas-based suppression Vindhya · VIN-613 series
- Protected volume
- 50-150 m³ to 1000-3000 m³ (see variants)
- Agent
- CO2
- Cylinder pressure
- 42 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 12 months from commissioning · MOQ 1 set
Gas-based suppressionThanjavurkiran5 variants
SampleGas-based suppression Thanjavurkiran · THA-4F7 series
- Protected volume
- Up to 50 m³ to 1000-3000 m³ (see variants)
- Agent
- HFC-227ea
- Cylinder pressure
- 25 bar
- Discharge time
- 60 seconds (inert gas)
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 12 months from commissioning · MOQ 10 set
Gas-based suppressionNilgiri4 variants
SampleGas-based suppression Nilgiri · NIL-346 series
- Protected volume
- 50-150 m³ to 1000-3000 m³ (see variants)
- Agent
- IG-541
- Cylinder pressure
- 25 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 8-12 weeks · Warranty 12 months from commissioning · MOQ 2 set
Gas-based suppressionSatavahanaspark4 variants
SampleGas-based suppression Satavahanaspark · SAT-4F7 series
- Protected volume
- 50-150 m³ to 1000-3000 m³ (see variants)
- Agent
- HFC-227ea
- Cylinder pressure
- 42 bar
- Discharge time
- 60 seconds (inert gas)
- Detection
- Cross-zoned smoke detectors
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 10 set
Gas-based suppressionAravalijal3 variants
SampleGas-based suppression Aravalijal · ARA-349 series
- Protected volume
- Up to 50 m³ to 150-400 m³ (see variants)
- Agent
- IG-541
- Cylinder pressure
- 42 bar
- Discharge time
- 10 seconds
- Detection
- Cross-zoned smoke detectors
Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 2 set