Power quality analysersBeas5 variants
SamplePower quality analysers Beas · BEA-319 series
- Type
- Panel meter Class S to Fixed PQ monitor Class A (see variants)
- Measurement class
- IEC 61000-4-30 Class S
- Voltage input
- Up to 1000 V CAT III
- Current input
- Rogowski coil
- Harmonics
- Up to 50th
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 5 nos
SCADA, RTU & plant controllersVaigaispark6 variants
SampleSCADA, RTU & plant controllers Vaigaispark · VAI-026 series
- I/O capacity
- 16 DI / 8 DO to 512 I/O modular (see variants)
- Protocols
- IEC 61850 server
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 36 months from supply · MOQ 1 nos
SCADA, RTU & plant controllersOjascore3 variants
SampleSCADA, RTU & plant controllers Ojascore · OJA-026 series
- I/O capacity
- 16 DI / 8 DO to 64 DI / 32 DO / 16 AI (see variants)
- Protocols
- DNP3
- CPU
- Industrial x86 dual-core
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 10 nos
Data loggersHampi5 variants
Hampi · HAM-376 series
- Channels
- 4 channels to 64 channels (see variants)
- Input types
- 0-10 V
- Resolution
- 16-bit
- Sampling rate
- 100 ms min
- Memory
- 2 GB
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 5 nos
Energy meters (smart, ABT, net)Lonavalatamra3 variants
SampleEnergy meters (smart, ABT, net) Lonavalatamra · LON-258 series
- Meter type
- 3-ph HT 3P4W 1 A to ABT 0.2S 3P3W (see variants)
- Accuracy class
- 0.5S
- Reference voltage
- 3x63.5/110 V
- Frequency
- 50 Hz
- Communication
- RF mesh
Lead time 2-3 weeks · Warranty 5 years from supply · MOQ 5 nos
Distribution transformer monitoring units (DTMU)Ajanta5 variants
SampleDistribution transformer monitoring units (DTMU) Ajanta · AJA-708 series
- DT rating covered
- Up to 63 kVA to 1250-2000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 1.0
- CT input
- CT 1000/1 A
- Communication
- GPRS/4G
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 2 nos
Data loggersKonarkanant5 variants
Konarkanant · KON-CF2 series
- Channels
- 4 channels to 64 channels (see variants)
- Input types
- 0-10 V
- Resolution
- 24-bit
- Sampling rate
- 100 ms min
- Memory
- 8 GB
Lead time 1-2 weeks · Warranty 24 months from supply · MOQ 5 nos
IoT & remote monitoringAiravatmax4 variants
SampleIoT & remote monitoring Airavatmax · AIR-5F2 series
- Channels / points
- 8 inputs to 64 inputs (see variants)
- Connectivity
- LoRaWAN
- Protocols
- OPC UA
- Serial ports
- 2 x RS-485
- Digital I/O
- 8 DI / 4 DO
Lead time 1-2 weeks · Warranty 24 months from supply · MOQ 5 nos
Meter test benches & CMRIHoysala5 variants
SampleMeter test benches & CMRI Hoysala · HOY-0B4 series
- Capacity
- CMRI handheld to 3-ph 3-position 0.05 (see variants)
- Reference accuracy
- 0.1%
- Voltage range
- 57.7-480 V
- Current range
- 0.001-100 A
- Source type
- Programmable electronic source
Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 1 nos
Power quality analysersKonkan3 variants
SamplePower quality analysers Konkan · KON-C01 series
- Type
- Portable 3-ph Class S to Fixed PQ monitor Class A (see variants)
- Measurement class
- IEC 61000-4-30 Class S
- Voltage input
- 57-690 V L-L
- Current input
- CT 1/5 A
- Harmonics
- Up to 50th
Lead time 2-4 weeks · Warranty 36 months from supply · MOQ 5 nos
IoT & remote monitoringBeas6 variants
SampleIoT & remote monitoring Beas · BEA-C96 series
- Channels / points
- 8 inputs to 256 inputs (see variants)
- Connectivity
- 4G LTE Cat 1
- Protocols
- Modbus RTU/TCP
- Serial ports
- 2 x RS-485 + 1 RS-232
- Digital I/O
- 4 DI / 2 DO
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos
Weather monitoring stationsAjanta3 variants
SampleWeather monitoring stations Ajanta · AJA-473 series
- Configuration
- Standard: GHI, POA, Tamb, Tmod to Class A: + albedo, DNI, DHI (see variants)
- Pyranometer class
- ISO 9060 Class B
- Wind sensor
- Cup anemometer
- Temperature sensor
- PT1000 back-of-module
- Humidity range
- 0-100% RH
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 10 set
Distribution transformer monitoring units (DTMU)Chola3 variants
SampleDistribution transformer monitoring units (DTMU) Chola · CHO-401 series
- DT rating covered
- 100-200 kVA to 500-1000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 1.0
- CT input
- Split-core CT 100/5 A
- Communication
- RF mesh
Lead time 6-8 weeks · Warranty 36 months from supply · MOQ 1 nos
Data loggersAiravatmax5 variants
Airavatmax · AIR-FA2 series
- Channels
- 4 channels to 64 channels (see variants)
- Input types
- 4-20 mA
- Resolution
- 16-bit
- Sampling rate
- 1 s min
- Memory
- 32 GB
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 10 nos
Energy meters (smart, ABT, net)Pennar6 variants
SampleEnergy meters (smart, ABT, net) Pennar · PEN-5C7 series
- Meter type
- 1-ph smart 5-30 A to ABT 0.2S 3P3W (see variants)
- Accuracy class
- 0.5S
- Reference voltage
- 240 V
- Frequency
- 50 Hz
- Communication
- GPRS/4G
Lead time 2-3 weeks · Warranty 60 months from installation · MOQ 10 nos
IoT & remote monitoringLonavalatamra4 variants
SampleIoT & remote monitoring Lonavalatamra · LON-565 series
- Channels / points
- 8 inputs to 64 inputs (see variants)
- Connectivity
- 4G LTE Cat 1
- Protocols
- OPC UA
- Serial ports
- 2 x RS-485
- Digital I/O
- 8 DI / 4 DO
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 5 nos
Data loggersAjanta3 variants
Ajanta · AJA-BB7 series
- Channels
- 4 channels to 16 channels (see variants)
- Input types
- Modbus RTU
- Resolution
- 16-bit
- Sampling rate
- 100 ms min
- Memory
- 8 GB
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos
IoT & remote monitoringHoysala6 variants
SampleIoT & remote monitoring Hoysala · HOY-5F4 series
- Channels / points
- 8 inputs to 256 inputs (see variants)
- Connectivity
- Ethernet + 4G
- Protocols
- Modbus RTU/TCP
- Serial ports
- 2 x RS-485 + 1 RS-232
- Digital I/O
- 8 DI / 4 DO
Lead time 3-4 weeks · Warranty 24 months from supply · MOQ 2 nos
Power quality analysersVaigaishakti6 variants
SamplePower quality analysers Vaigaishakti · VAI-556 series
- Type
- Panel meter Class S to Fixed PQ + waveform capture (see variants)
- Measurement class
- IEC 61000-4-30 Class S
- Voltage input
- 57-690 V L-L
- Current input
- CT 1/5 A
- Harmonics
- Up to 50th
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 1 nos
Power quality analysersAwadh3 variants
SamplePower quality analysers Awadh · AWA-732 series
- Type
- Portable 3-ph Class S to Fixed PQ monitor Class A (see variants)
- Measurement class
- IEC 61000-4-30 Class S
- Voltage input
- 57-690 V L-L
- Current input
- CT 1/5 A
- Harmonics
- Up to 63rd
Lead time 6-8 weeks · Warranty 36 months from supply · MOQ 2 nos
SCADA, RTU & plant controllersVaigaispark5 variants
SampleSCADA, RTU & plant controllers Vaigaispark · VAI-3C2 series
- I/O capacity
- 16 DI / 8 DO to 256 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- Industrial x86 dual-core
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 36 months from supply · MOQ 10 nos
Distribution transformer monitoring units (DTMU)Faradayline4 variants
SampleDistribution transformer monitoring units (DTMU) Faradayline · FAR-E79 series
- DT rating covered
- Up to 63 kVA to 500-1000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 0.5S
- CT input
- CT 1000/1 A
- Communication
- RF mesh
Lead time 3-4 weeks · Warranty 36 months from supply · MOQ 1 nos
AMI head-end & meter data managementAiravatmax6 variants
SampleAMI head-end & meter data management Airavatmax · AIR-8D4 series
- Meter capacity
- 50,000 meters to 2,500,000 meters (see variants)
- Deployment
- On-premise
- Protocols
- IEC 61968-9
- Communication support
- RF mesh
- Data validation
- VEE rules engine
Lead time 10-14 weeks · Warranty 12 months with AMC option · MOQ 1 licence
Distribution transformer monitoring units (DTMU)Prabhacore5 variants
SampleDistribution transformer monitoring units (DTMU) Prabhacore · PRA-2A7 series
- DT rating covered
- Up to 63 kVA to 1250-2000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 1.0
- CT input
- CT 1000/1 A
- Communication
- RF mesh
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 10 nos