Fire protection

Detection, suppression and passive fire protection.

Companies offering this · 18

Listings (287)

Prices are shown to verified buyers. Register your company to see them and request quotes.

Fire pump set (electric + diesel), Max series

SampleHydrant & sprinkler systems

Brahmaputra · BRA-E74 series

Pump capacity
410 m³/h at 88 m to 684 m³/h at 88 m (see variants)
Pump type
End suction centrifugal
Drivers
Electric motor
Jockey pump
10.8 m³/h at 88 m
Pipe
MS Class C with epoxy paint

Lead time 12-16 weeks · Warranty 24 months from supply · MOQ 1 lot

Price for verified buyers

by Brahmaputra Fire Systems (Sample) · invoiced by BARREL

Request quote

Fire-rated cable transit block, Xtra 6 series

SampleFire-rated coatings & penetration seals

Beas · BEA-283 series

Fire rating
30 min to 180 min (see variants)
Product type
Fire-stop acrylic sealant
Application
Gun-applied
Thickness
1 mm wet
Smoke and toxicity
Low smoke, halogen-free

Lead time 2-3 weeks · Warranty 10 years performance (system) · MOQ 10 kg

Price on quote

by Beas Fire Engineers (Sample) · invoiced by BARREL

Request quote

Air-sampling smoke detector, Core 9 series

SampleAspirating smoke detection

Gridtek · GRI-F06 series

Coverage
Up to 250 m² / 1 pipe to Up to 2000 m² (see variants)
Sensitivity
Class B
Detection
Laser light scattering
Alarm levels
Alert, Action, Fire 1, Fire 2
Pipe network
Up to 100 m

Lead time 3-4 weeks · Warranty 36 months from supply · MOQ 1 nos

Price on quote

by Gridtek Fire Engineers (Sample) · invoiced by BARREL

Request quote

Vindhya · VIN-5A2 series

Coverage
Up to 1000 m² / 4 pipes to Up to 4000 m² (see variants)
Sensitivity
Class A (very high)
Detection
Laser light scattering
Alarm levels
Alert, Action, Fire 1, Fire 2
Pipe network
Up to 400 m

Lead time 6-8 weeks · Warranty 36 months from supply · MOQ 1 nos

Price for verified buyers

by Vindhya Fire Systems (Sample) · invoiced by BARREL

Request quote

Intumescent fire-retardant cable coating, Flex 3 series

SampleFire-rated coatings & penetration seals

Thanjavurkiran · THA-561 series

Fire rating
30 min to 120 min (see variants)
Product type
Water-based intumescent coating
Application
Brush or airless spray
Thickness
1 mm wet
Smoke and toxicity
Low smoke, halogen-free

Lead time 2-3 weeks · Warranty 10 years performance (system) · MOQ 1 kg

Price for verified buyers

by Thanjavurkiran Fire Engineers (Sample) · invoiced by BARREL

Request quote

Fire-rated cable transit block, Elite series

SampleFire-rated coatings & penetration seals

Satavahanaspark · SAT-282 series

Fire rating
60 min to 180 min (see variants)
Product type
Fire-stop acrylic sealant
Application
Fitted into frame
Thickness
2 mm DFT
Smoke and toxicity
Low smoke, halogen-free

Lead time 1-2 weeks · Warranty 12 months shelf life · MOQ 1 kg

Price for verified buyers

by Satavahanaspark Fire Systems (Sample) · invoiced by BARREL

Request quote

Vindhya · VIN-FB7 series

Panel loops / zones
8 zones conventional to 2 loop addressable (see variants)
Panel type
Addressable (analogue)
Loop capacity
250 devices per loop
Display
Alphanumeric LCD
Network
Up to 32 panels

Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 5 nos

Price for verified buyers

by Vindhya Fire Systems (Sample) · invoiced by BARREL

Request quote

Konarkakshay · KON-7D1 series

Coverage
Up to 250 m² / 1 pipe to Up to 1000 m² / 4 pipes (see variants)
Sensitivity
Class B
Detection
Laser light scattering
Alarm levels
Alert, Action, Fire 1, Fire 2
Pipe network
Up to 400 m

Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 1 nos

Price for verified buyers

by Konarkakshay Fire Protection (Sample) · invoiced by BARREL

Request quote

Rajatgen · RAJ-6E3 series

Panel loops / zones
8 zones conventional to 4 loop addressable (see variants)
Panel type
Addressable (analogue)
Loop capacity
127 devices
Display
Alphanumeric LCD
Network
Up to 32 panels

Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price for verified buyers

by Rajatgen Fire Systems (Sample) · invoiced by BARREL

Request quote

Teestavajra · TEE-5A6 series

Coverage
Up to 250 m² / 1 pipe to Up to 2000 m² (see variants)
Sensitivity
Class C
Detection
Laser light scattering
Alarm levels
Alert, Action, Fire 1, Fire 2
Pipe network
Up to 400 m

Lead time 3-4 weeks · Warranty 36 months from supply · MOQ 10 nos

Price for verified buyers

by Teestavajra Fire Engineers (Sample) · invoiced by BARREL

Request quote

Air-sampling smoke detector, Prime 3 series

SampleAspirating smoke detection

Jhelumfaraday · JHE-F05 series

Coverage
Up to 250 m² / 1 pipe to Up to 2000 m² (see variants)
Sensitivity
Class A (very high)
Detection
Laser light scattering
Alarm levels
Alert, Action, Fire 1, Fire 2
Pipe network
Up to 400 m

Lead time 3-4 weeks · Warranty 36 months from supply · MOQ 5 nos

Price on quote

by Jhelumfaraday Fire Engineers (Sample) · invoiced by BARREL

Request quote

Multi-criteria heat detector, Plus series

SampleFire detection & alarm

Rajatgen · RAJ-4B4 series

Panel loops / zones
4 zones conventional to 2 loop addressable (see variants)
Panel type
Conventional
Loop capacity
127 devices
Display
Graphic touch
Network
Up to 32 panels

Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 5 nos

Price for verified buyers

by Rajatgen Fire Systems (Sample) · invoiced by BARREL

Request quote

Fire-stop sealant for penetrations, Smart series

SampleFire-rated coatings & penetration seals

Betwa · BET-E78 series

Fire rating
30 min to 180 min (see variants)
Product type
Fire-stop acrylic sealant
Application
Gun-applied
Thickness
50 mm board
Smoke and toxicity
Low smoke, halogen-free

Lead time 1-2 weeks · Warranty 12 months shelf life · MOQ 1 kg

Price for verified buyers

by Betwa Fire Engineers (Sample) · invoiced by BARREL

Request quote

Gridtek · GRI-5C1 series

Coverage
Up to 1000 m² / 4 pipes to Up to 4000 m² (see variants)
Sensitivity
Class A (very high)
Detection
Laser light scattering
Alarm levels
Alert, Action, Fire 1, Fire 2
Pipe network
Up to 100 m

Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 1 nos

Price on quote

by Gridtek Fire Engineers (Sample) · invoiced by BARREL

Request quote

Aravalijal · ARA-236 series

Panel loops / zones
8 zones conventional to 4 loop addressable (see variants)
Panel type
Addressable (analogue)
Loop capacity
127 devices
Display
Graphic touch
Network
Up to 32 panels

Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price for verified buyers

by Aravalijal Fire Protection (Sample) · invoiced by BARREL

Request quote

CO2 total flooding system, Plus series

SampleGas-based suppression

Betwa · BET-FA9 series

Protected volume
Up to 50 m³ to 1000-3000 m³ (see variants)
Agent
FK-5-1-12
Cylinder pressure
300 bar
Discharge time
60 seconds (inert gas)
Detection
Cross-zoned smoke detectors

Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 1 set

Price on quote

by Betwa Fire Engineers (Sample) · invoiced by BARREL

Request quote

Beas · BEA-CC1 series

Protected volume
Up to 50 m³ to 400-1000 m³ (see variants)
Agent
CO2
Cylinder pressure
42 bar
Discharge time
10 seconds
Detection
Cross-zoned smoke detectors

Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 2 set

Price for verified buyers

by Beas Fire Engineers (Sample) · invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited