Awadh Xtra cable test set 0.1 Hz, offered in 6 test voltage (VLF peak) options from 28 kV to 90 kV. Key features: PD location along cable length, tan delta diagnostics on XLPE cable and compact for cable testing in the field. Used by generator winding assessment, MV and HV cable commissioning and switchgear PD survey. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 8-14 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Awadh
- Model
- AWA-912 series
- Listing type
- Product
- Unit
- set
- Minimum order
- 5 set
- Lead time
- 8-14 weeks
- Warranty
- 24 months with calibration
- Standards
- IEC 60270, IEEE 400.2, IEC 60840
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Test voltage (VLF peak)28 kVAWA-912-01 | Test voltage (VLF peak): 28 kV | 5 set · 8-14 weeks | on quote |
| Test voltage (VLF peak)34 kVAWA-912-02 | Test voltage (VLF peak): 34 kV | 5 set · 8-14 weeks | on quote |
| Test voltage (VLF peak)50 kVAWA-912-03 | Test voltage (VLF peak): 50 kV | 5 set · 8-14 weeks | on quote |
| Test voltage (VLF peak)60 kVAWA-912-04 | Test voltage (VLF peak): 60 kV | 5 set · 8-14 weeks | on quote |
| Test voltage (VLF peak)80 kVAWA-912-05 | Test voltage (VLF peak): 80 kV | 5 set · 8-14 weeks | on quote |
| Test voltage (VLF peak)90 kVAWA-912-06 | Test voltage (VLF peak): 90 kV | 5 set · 8-14 weeks | on quote |
Specifications
| Test voltage (VLF peak) | 28 kV to 90 kV (see variants) |
|---|---|
| Test frequency | 0.1 Hz |
| Waveform | Sinusoidal |
| Max load capacitance | 1.1 microF |
| PD sensitivity | Below 5 pC |
| PD detection | Bothmade to order: Offline / Online |
| Measurement range | 1-10000 pC |
| Diagnostics | Tan delta option |
| Power supply | 230 V AC |
| Weight | 50 kg |