Partial discharge & VLF testersKonarkakshay6 variants
SamplePartial discharge & VLF testers Konarkakshay · KON-D43 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 1 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersHoysala3 variants
SamplePartial discharge & VLF testers Hoysala · HOY-599 series
- Test voltage (VLF peak)
- 28 kV to 50 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 10 set
Partial discharge & VLF testersMaurya6 variants
SamplePartial discharge & VLF testers Maurya · MAU-335 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersShaktimark5 variants
SamplePartial discharge & VLF testers Shaktimark · SHA-334 series
- Test voltage (VLF peak)
- 28 kV to 80 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersAkshaymark3 variants
SamplePartial discharge & VLF testers Akshaymark · AKS-915 series
- Test voltage (VLF peak)
- 50 kV to 80 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersEllora4 variants
SamplePartial discharge & VLF testers Ellora · ELL-332 series
- Test voltage (VLF peak)
- 34 kV to 80 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 1 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 1 set
Partial discharge & VLF testersNarmadaphase3 variants
SamplePartial discharge & VLF testers Narmadaphase · NAR-332 series
- Test voltage (VLF peak)
- 60 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 1 pC
Lead time 4-6 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersSetucore5 variants
SamplePartial discharge & VLF testers Setucore · SET-597 series
- Test voltage (VLF peak)
- 34 kV to 90 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersKamrupsamarth4 variants
SamplePartial discharge & VLF testers Kamrupsamarth · KAM-914 series
- Test voltage (VLF peak)
- 50 kV to 90 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 10 set
Partial discharge & VLF testersShivalik3 variants
SamplePartial discharge & VLF testers Shivalik · SHI-334 series
- Test voltage (VLF peak)
- 28 kV to 50 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 1 pC
Lead time 4-6 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersKamrupsamarth6 variants
SamplePartial discharge & VLF testers Kamrupsamarth · KAM-334 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 1 set
Partial discharge & VLF testersKalingavajra6 variants
SamplePartial discharge & VLF testers Kalingavajra · KAL-333 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 24 months with calibration · MOQ 1 set
Partial discharge & VLF testersAwadh6 variants
SamplePartial discharge & VLF testers Awadh · AWA-912 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 5 set
Partial discharge & VLF testersHoysala5 variants
SamplePartial discharge & VLF testers Hoysala · HOY-D43 series
- Test voltage (VLF peak)
- 34 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 12 months from supply · MOQ 10 set
Partial discharge & VLF testersSudarshanmark6 variants
SamplePartial discharge & VLF testers Sudarshanmark · SUD-598 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 1 pC
Lead time 8-14 weeks · Warranty 12 months from supply · MOQ 2 set
Partial discharge & VLF testersVijaya4 variants
SamplePartial discharge & VLF testers Vijaya · VIJ-D46 series
- Test voltage (VLF peak)
- 28 kV to 60 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 12 months from supply · MOQ 1 set
Partial discharge & VLF testersMahanadi5 variants
SamplePartial discharge & VLF testers Mahanadi · MAH-591 series
- Test voltage (VLF peak)
- 34 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 5 set
Partial discharge & VLF testersDeccan4 variants
SamplePartial discharge & VLF testers Deccan · DEC-596 series
- Test voltage (VLF peak)
- 50 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 12 months from supply · MOQ 2 set
Partial discharge & VLF testersPushpakline6 variants
SamplePartial discharge & VLF testers Pushpakline · PUS-914 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 2 set
Partial discharge & VLF testersMahanadi3 variants
SamplePartial discharge & VLF testers Mahanadi · MAH-D47 series
- Test voltage (VLF peak)
- 28 kV to 50 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 1 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 1 set
Partial discharge & VLF testersNarmadaphase5 variants
SamplePartial discharge & VLF testers Narmadaphase · NAR-917 series
- Test voltage (VLF peak)
- 34 kV to 90 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Sinusoidal
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 2 set
Partial discharge & VLF testersDwarakasamarth3 variants
SamplePartial discharge & VLF testers Dwarakasamarth · DWA-D49 series
- Test voltage (VLF peak)
- 34 kV to 60 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 2 set
Partial discharge & VLF testersMadurai4 variants
SamplePartial discharge & VLF testers Madurai · MAD-333 series
- Test voltage (VLF peak)
- 50 kV to 90 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 1 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 5 set
Partial discharge & VLF testersBrahmaputra4 variants
SamplePartial discharge & VLF testers Brahmaputra · BRA-912 series
- Test voltage (VLF peak)
- 50 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 1 set