Catalogue / Partial discharge & VLF testers

No photo yet

Offline PD measurement system, Smart seriesSample

by Sudarshanmark Test Instruments (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Sudarshanmark Test Instruments (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Sudarshanmark Smart offline PD measurement system, offered in 6 test voltage (VLF peak) options from 28 kV to 90 kV. Design: safety interlock and discharge rod, tan delta diagnostics on XLPE cable and compact for cable testing in the field. Typically used for switchgear PD survey, MV and HV cable commissioning and cable diagnostics. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 8-14 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Sudarshanmark
Model
SUD-598 series
Listing type
Product
Unit
set
Minimum order
2 set
Lead time
8-14 weeks
Warranty
12 months from supply
Standards
IEC 60270, IEEE 400.2, IEC 60840
Delivers to
South India
GST rate
18 %
Country of origin
India
Packaging
Drum / reel with end caps
Delivery terms
Ex-works, freight extra at actuals
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Test voltage (VLF peak)28 kVSUD-598-01Test voltage (VLF peak): 28 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)34 kVSUD-598-02Test voltage (VLF peak): 34 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)50 kVSUD-598-03Test voltage (VLF peak): 50 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)60 kVSUD-598-04Test voltage (VLF peak): 60 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)80 kVSUD-598-05Test voltage (VLF peak): 80 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)90 kVSUD-598-06Test voltage (VLF peak): 90 kV2 set · 8-14 weeksfor verified buyers

Specifications

Test voltage (VLF peak)28 kV to 90 kV (see variants)
Test frequency0.1 Hzmade to order: 0.05 Hz to 0.1 Hz
WaveformCosine rectangular
Max load capacitance1.1 microFmade to order: 0.5 microF
PD sensitivityBelow 1 pCmade to order: Below 5 pC
PD detectionOnline
Measurement range1-10000 pC
DiagnosticsTan delta option
Power supply230 V AC
Weight50 kg
OperationTouch screen PC controlled