Catalogue / Partial discharge & VLF testers
Cable test set 0.1 Hz, Volt 4 seriesSample
by Narmadaphase Test Instruments (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Narmadaphase Test Instruments (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Volt 4 range of cable test set 0.1 Hz by Narmadaphase covers 5 test voltage (VLF peak) options (34 kV to 90 kV). Design: compact for cable testing in the field, software report with PD map and PD location along cable length. Suited to cable diagnostics, generator winding assessment and switchgear PD survey. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 8-14 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Narmadaphase
- Model
- NAR-917 series
- Listing type
- Product
- Unit
- set
- Minimum order
- 2 set
- Lead time
- 8-14 weeks
- Warranty
- 24 months with calibration
- Standards
- IEC 60270, IEEE 400.2, IEC 60840
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Test voltage (VLF peak)34 kVNAR-917-01 | Test voltage (VLF peak): 34 kV | 2 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)50 kVNAR-917-02 | Test voltage (VLF peak): 50 kV | 2 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)60 kVNAR-917-03 | Test voltage (VLF peak): 60 kV | 2 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)80 kVNAR-917-04 | Test voltage (VLF peak): 80 kV | 2 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)90 kVNAR-917-05 | Test voltage (VLF peak): 90 kV | 2 set · 8-14 weeks | for verified buyers |
Specifications
| Test voltage (VLF peak) | 34 kV to 90 kV (see variants) |
|---|---|
| Test frequency | 0.05 Hz to 0.1 Hzmade to order: 0.1 Hz |
| Waveform | Sinusoidalmade to order: Cosine rectangular |
| Max load capacitance | 0.5 microFmade to order: 1.1 microF |
| PD sensitivity | Below 5 pC |
| PD detection | Onlinemade to order: Offline / Both |
| Measurement range | 1-10000 pC |
| Diagnostics | Tan delta option |
| Power supply | 230 V AC |
| Weight | 50 kgmade to order: 85 kg |
| Operation | Touch screen PC controlled |