Catalogue / Partial discharge & VLF testers

No photo yet

Cable test set 0.1 Hz, Eco seriesSample

by Pushpakline Testing Solutions (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Pushpakline Testing Solutions (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Pushpakline Eco cable test set 0.1 Hz, offered in 6 test voltage (VLF peak) options from 28 kV to 90 kV. Highlights: software report with PD map, automatic voltage ramp and tan delta diagnostics on XLPE cable. Typically used for switchgear PD survey, generator winding assessment and cable diagnostics. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 4-6 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Pushpakline
Model
PUS-914 series
Listing type
Product
Unit
set
Minimum order
2 set
Lead time
4-6 weeks
Warranty
12 months from supply
Standards
IEC 60270, IEEE 400.2, IEC 60840
Delivers to
South India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
FOR site, freight included
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Test voltage (VLF peak)28 kVPUS-914-01Test voltage (VLF peak): 28 kV2 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)34 kVPUS-914-02Test voltage (VLF peak): 34 kV2 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)50 kVPUS-914-03Test voltage (VLF peak): 50 kV2 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)60 kVPUS-914-04Test voltage (VLF peak): 60 kV2 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)80 kVPUS-914-05Test voltage (VLF peak): 80 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)90 kVPUS-914-06Test voltage (VLF peak): 90 kV2 set · 8-14 weeksfor verified buyers

Specifications

Test voltage (VLF peak)28 kV to 90 kV (see variants)
Test frequency0.1 Hz
WaveformSinusoidal
Max load capacitance0.5 microF
PD sensitivityBelow 5 pC
PD detectionOnlinemade to order: Offline / Both
Measurement range1-10000 pC
DiagnosticsTan delta option
Power supply230 V AC
Weight85 kg
OperationTouch screen PC controlled

BARREL: Bharat Atom Renewable Resources Energy Limited