Catalogue / Partial discharge & VLF testers
Partial discharge detector, Core seriesSample
by Hoysala Test Equipment (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Hoysala Test Equipment (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Core range of partial discharge detector by Hoysala covers 5 test voltage (VLF peak) options (34 kV to 90 kV). Design: safety interlock and discharge rod, software report with PD map and automatic voltage ramp. Used by cable diagnostics, switchgear PD survey and generator winding assessment. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 8-14 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Hoysala
- Model
- HOY-D43 series
- Listing type
- Product
- Unit
- set
- Minimum order
- 10 set
- Lead time
- 8-14 weeks
- Warranty
- 12 months from supply
- Standards
- IEC 60270, IEEE 400.2, IEC 60840
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Test voltage (VLF peak)34 kVHOY-D43-01 | Test voltage (VLF peak): 34 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)50 kVHOY-D43-02 | Test voltage (VLF peak): 50 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)60 kVHOY-D43-03 | Test voltage (VLF peak): 60 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)80 kVHOY-D43-04 | Test voltage (VLF peak): 80 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)90 kVHOY-D43-05 | Test voltage (VLF peak): 90 kV | 10 set · 8-14 weeks | for verified buyers |
Specifications
| Test voltage (VLF peak) | 34 kV to 90 kV (see variants) |
|---|---|
| Test frequency | 0.1 Hz |
| Waveform | Sinusoidal |
| Max load capacitance | 1.1 microF |
| PD sensitivity | Below 5 pC |
| PD detection | Offlinemade to order: Online / Both |
| Measurement range | 1-10000 pC |
| Diagnostics | Tan delta option |
| Power supply | 230 V AC |
| Weight | 85 kgmade to order: 50 kg |
| Operation | Touch screen PC controlled |