VLF very low frequency test set, Volt seriesSample

by Kalingavajra Testing Solutions (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kalingavajra Testing Solutions (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Kalingavajra Volt VLF very low frequency test set, offered in 6 test voltage (VLF peak) options from 28 kV to 90 kV. Key features: compact for cable testing in the field, safety interlock and discharge rod and PD location along cable length. Typically used for cable diagnostics, MV and HV cable commissioning and generator winding assessment. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 4-6 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kalingavajra
Model
KAL-333 series
Listing type
Product
Unit
set
Minimum order
1 set
Lead time
4-6 weeks
Warranty
24 months with calibration
Standards
IEC 60270, IEEE 400.2, IEC 60840
Delivers to
North India
GST rate
18 %
Country of origin
India
Packaging
As per item, transit-safe
Delivery terms
Door delivery in metro cities
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Test voltage (VLF peak)28 kVKAL-333-01Test voltage (VLF peak): 28 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)34 kVKAL-333-02Test voltage (VLF peak): 34 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)50 kVKAL-333-03Test voltage (VLF peak): 50 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)60 kVKAL-333-04Test voltage (VLF peak): 60 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)80 kVKAL-333-05Test voltage (VLF peak): 80 kV1 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)90 kVKAL-333-06Test voltage (VLF peak): 90 kV1 set · 8-14 weeksfor verified buyers

Specifications

Test voltage (VLF peak)28 kV to 90 kV (see variants)
Test frequency0.05 Hz to 0.1 Hz
WaveformCosine rectangularmade to order: Sinusoidal
Max load capacitance0.5 microF
PD sensitivityBelow 5 pCmade to order: Below 1 pC
PD detectionBothmade to order: Offline / Online
Measurement range1-10000 pC
DiagnosticsTan delta option
Power supply230 V AC
Weight85 kgmade to order: 50 kg
OperationTouch screen PC controlled