Catalogue / Partial discharge & VLF testers
Offline PD measurement system, Max seriesSample
by Mahanadi Test Instruments (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mahanadi Test Instruments (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Max range of offline PD measurement system by Mahanadi covers 5 test voltage (VLF peak) options (34 kV to 90 kV). Key features: PD location along cable length, compact for cable testing in the field and safety interlock and discharge rod. Suited to generator winding assessment, cable diagnostics and switchgear PD survey. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 4-6 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mahanadi
- Model
- MAH-591 series
- Listing type
- Product
- Unit
- set
- Minimum order
- 5 set
- Lead time
- 4-6 weeks
- Warranty
- 12 months from supply
- Standards
- IEC 60270, IEEE 400.2, IEC 60840
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Test voltage (VLF peak)34 kVMAH-591-01 | Test voltage (VLF peak): 34 kV | 5 set · 4-6 weeks | for verified buyers |
| Test voltage (VLF peak)50 kVMAH-591-02 | Test voltage (VLF peak): 50 kV | 5 set · 4-6 weeks | for verified buyers |
| Test voltage (VLF peak)60 kVMAH-591-03 | Test voltage (VLF peak): 60 kV | 5 set · 4-6 weeks | for verified buyers |
| Test voltage (VLF peak)80 kVMAH-591-04 | Test voltage (VLF peak): 80 kV | 5 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)90 kVMAH-591-05 | Test voltage (VLF peak): 90 kV | 5 set · 8-14 weeks | for verified buyers |
Specifications
| Test voltage (VLF peak) | 34 kV to 90 kV (see variants) |
|---|---|
| Test frequency | 0.1 Hzmade to order: 0.05 Hz to 0.1 Hz |
| Waveform | Cosine rectangularmade to order: Sinusoidal |
| Max load capacitance | 1.1 microFmade to order: 0.5 microF |
| PD sensitivity | Below 5 pC |
| PD detection | Onlinemade to order: Offline / Both |
| Measurement range | 1-10000 pC |
| Diagnostics | Tan delta option |
| Power supply | 230 V AC |
| Weight | 50 kgmade to order: 85 kg |
| Operation | Touch screen PC controlled |