Catalogue / Partial discharge & VLF testers
Cable test set 0.1 Hz, Xtra seriesSample
by Coromandel Testing Solutions (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Coromandel Testing Solutions (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Coromandel Xtra cable test set 0.1 Hz, offered in 6 test voltage (VLF peak) options from 28 kV to 90 kV. Key features: safety interlock and discharge rod, automatic voltage ramp and software report with PD map. Used by switchgear PD survey, cable diagnostics and generator winding assessment. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 8-14 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Coromandel
- Model
- COR-914 series
- Listing type
- Product
- Unit
- set
- Minimum order
- 10 set
- Lead time
- 8-14 weeks
- Warranty
- 12 months from supply
- Standards
- IEC 60270, IEEE 400.2, IEC 60840
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Test voltage (VLF peak)28 kVCOR-914-01 | Test voltage (VLF peak): 28 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)34 kVCOR-914-02 | Test voltage (VLF peak): 34 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)50 kVCOR-914-03 | Test voltage (VLF peak): 50 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)60 kVCOR-914-04 | Test voltage (VLF peak): 60 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)80 kVCOR-914-05 | Test voltage (VLF peak): 80 kV | 10 set · 8-14 weeks | for verified buyers |
| Test voltage (VLF peak)90 kVCOR-914-06 | Test voltage (VLF peak): 90 kV | 10 set · 8-14 weeks | for verified buyers |
Specifications
| Test voltage (VLF peak) | 28 kV to 90 kV (see variants) |
|---|---|
| Test frequency | 0.05 Hz to 0.1 Hzmade to order: 0.1 Hz |
| Waveform | Cosine rectangular |
| Max load capacitance | 0.5 microF |
| PD sensitivity | Below 5 pCmade to order: Below 1 pC |
| PD detection | Offlinemade to order: Online / Both |
| Measurement range | 1-10000 pC |
| Diagnostics | Tan delta option |
| Power supply | 230 V AC |
| Weight | 50 kg |
| Operation | Touch screen PC controlled |