The Ultra 3 range of partial discharge detector by Deccanarc covers 6 test voltage (VLF peak) options (28 kV to 90 kV). Key features: software report with PD map, PD location along cable length and automatic voltage ramp. Used by generator winding assessment, switchgear PD survey and cable diagnostics. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 8-14 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Deccanarc
Model
DEC-D43 series
Listing type
Product
Unit
set
Minimum order
2 set
Lead time
8-14 weeks
Warranty
24 months with calibration
Standards
IEC 60270, IEEE 400.2, IEC 60840
Delivers to
West India
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
FOR nearest railhead
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Test voltage (VLF peak)28 kVDEC-D43-01Test voltage (VLF peak): 28 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)34 kVDEC-D43-02Test voltage (VLF peak): 34 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)50 kVDEC-D43-03Test voltage (VLF peak): 50 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)60 kVDEC-D43-04Test voltage (VLF peak): 60 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)80 kVDEC-D43-05Test voltage (VLF peak): 80 kV2 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)90 kVDEC-D43-06Test voltage (VLF peak): 90 kV2 set · 8-14 weeksfor verified buyers

Specifications

Test voltage (VLF peak)28 kV to 90 kV (see variants)
Test frequency0.05 Hz to 0.1 Hz
WaveformCosine rectangularmade to order: Sinusoidal
Max load capacitance1.1 microFmade to order: 0.5 microF
PD sensitivityBelow 5 pC
PD detectionOfflinemade to order: Online / Both
Measurement range1-10000 pC
DiagnosticsTan delta option
Power supply230 V AC
Weight50 kg
OperationTouch screen PC controlled