Catalogue / Power system studies (load flow, short circuit, grid code)
Harmonic and power quality study, Neo 9 seriesSample
by Deccan Engineering Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Deccan Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Neo 9 service of harmonic and power quality study by Deccan covers 3 network scale options (66 kV system to 220 kV system). Key features: fault level verification of switchgear, PSS/E and PSCAD model support and reactive power capability curves. Used by renewable developers seeking connectivity, utilities and consultants and industrial plants adding generation. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation Kick-off in 1 week; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Deccan
- Model
- DEC-4B1 series
- Listing type
- Service
- Unit
- report
- Minimum order
- 1 report
- Lead time
- Kick-off in 1 week
- Warranty
- Revision for utility comments
- Standards
- CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Network scale66 kV systemDEC-4B1-01 | Network scale: 66 kV system | 1 report · Kick-off in 1 week | on quote |
| Network scale132 kV systemDEC-4B1-02 | Network scale: 132 kV system | 1 report · Kick-off in 1 week | on quote |
| Network scale220 kV systemDEC-4B1-03 | Network scale: 220 kV system | 1 report · Kick-off in 1 week | on quote |
Specifications
| Network scale | 66 kV system to 220 kV system (see variants) |
|---|---|
| Study type | Protection coordination |
| Software | PSS/E |
| Model data | Utility network modelmade to order: Client single line diagram and data |
| Deliverables | Model files and relay settings |
| Grid code checks | Voltage and reactive power capabilitymade to order: LVRT/HVRT and ramp rate |
| Review | Utility submission supportmade to order: Lender review |
| Scenarios | Multiple dispatch cases |
| Team | Power system engineer |
| Turnaround | 4-6 weeks |
| Validation | Peer review |