Catalogue / Site acceptance & pre-commissioning tests
Site acceptance testing for solar plants, Edge 9 seriesSample
by Deccan Engineering Services (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Deccan Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Deccan Edge 9 site acceptance testing for solar plants, offered in 4 plant size options from 10 MW to 100 MW. Design: instrument calibration certificates, checklist driven testing and support to CEIG inspection. Typically used for EPC handover, renewable parks and industrial substations. Delivered in line with IEC 62446-1, IS 3043 and IEC 61557. Mobilisation Mobilisation in 3-7 days; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Deccan
- Model
- DEC-241 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Mobilisation in 3-7 days
- Warranty
- Retest at no cost on instrument error
- Standards
- IEC 62446-1, IS 3043, IEC 61557
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Plant size10 MWDEC-241-01 | Plant size: 10 MW | 1 site · Mobilisation in 3-7 days | for verified buyers |
| Plant size25 MWDEC-241-02 | Plant size: 25 MW | 1 site · Mobilisation in 3-7 days | for verified buyers |
| Plant size50 MWDEC-241-03 | Plant size: 50 MW | 1 site · On-site 3-21 days | for verified buyers |
| Plant size100 MWDEC-241-04 | Plant size: 100 MW | 1 site · On-site 3-21 days | for verified buyers |
Specifications
| Plant size | 10 MW to 100 MW (see variants) |
|---|---|
| Scope | Electrical pre-commissioning |
| Instruments | Relay test set, IV tracer, CRM |
| Test sequence | Per client approved format |
| Team | Test engineer plus 2 techniciansmade to order: Team of 6 with lead |
| Duration on site | 10 daysmade to order: 3-5 days / 3 weeks |
| Reports | Digital dossier with photos |
| Calibration | Calibration certificates attached |
| Witnessed by | Client engineermade to order: Lender engineer or authority |
| Retest policy | One retest included |
| Payment | 50% advancemade to order: On completion of report |