Catalogue / Substation construction
Control and relay panel installation, Volt 3 seriesSample
by Deepmark Infra Services (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Deepmark Infra Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Deepmark Volt 3 control and relay panel installation, offered in 6 voltage class options from 11 kV to 400 kV. Key features: battery and DC system installation, full documentation pack and as-built and earth grid designed for fault level and soil resistivity. Used by industrial captive substations, data centre power infrastructure and renewable pooling stations. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Engineering in 4-6 weeks; serves South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Deepmark
- Model
- DEE-835 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Engineering in 4-6 weeks
- Warranty
- Defect liability 24 months
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class11 kVDEE-835-01 | Voltage class: 11 kV | 1 bay · Engineering in 4-6 weeks | for verified buyers |
| Voltage class33 kVDEE-835-02 | Voltage class: 33 kV | 1 bay · Engineering in 4-6 weeks | for verified buyers |
| Voltage class66 kVDEE-835-03 | Voltage class: 66 kV | 1 bay · Engineering in 4-6 weeks | for verified buyers |
| Voltage class132 kVDEE-835-04 | Voltage class: 132 kV | 1 bay · Engineering in 4-6 weeks | for verified buyers |
| Voltage class220 kVDEE-835-05 | Voltage class: 220 kV | 1 bay · Execution 6-15 months | for verified buyers |
| Voltage class400 kVDEE-835-06 | Voltage class: 400 kV | 1 bay · Execution 6-15 months | for verified buyers |
Specifications
| Voltage class | 11 kV to 400 kV (see variants) |
|---|---|
| Type | Hybrid GIS |
| Scope | Erection and testing |
| Transformers | Up to 315 MVA |
| Earthing | GI flat grid with ground rods |
| Bay count | 2-4 bays |
| Protection scheme | Main-1 and Main-2 relays |
| SCADA and communication | IEC 60870-5-104 |
| Statutory | STU charging approvalmade to order: CEIG inspection support |
| Duration | 12-15 monthsmade to order: 6-9 months |
| Payment terms | Percentage on supply, erectionmade to order: Milestone: 10/70/10/10 |