Catalogue / Substation construction
Switchyard erection and bus bar works, Prime 2 seriesSample
by Kalingaamrit Infra Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kalingaamrit Infra Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Switchyard erection and bus bar works from Kalingaamrit, Prime 2 series: 5 voltage class options between 33 kV and 400 kV. Key features: control room cabling and glanding, fire protection and oil soak pits and pre-commissioning tests before CEIG visit. Typically used for state utility augmentation, industrial captive substations and data centre power infrastructure. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Engineering in 4-6 weeks; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kalingaamrit
- Model
- KAL-093 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Engineering in 4-6 weeks
- Warranty
- Defect liability 24 months
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class33 kVKAL-093-01 | Voltage class: 33 kV | 1 bay · Engineering in 4-6 weeks | on quote |
| Voltage class66 kVKAL-093-02 | Voltage class: 66 kV | 1 bay · Engineering in 4-6 weeks | on quote |
| Voltage class132 kVKAL-093-03 | Voltage class: 132 kV | 1 bay · Engineering in 4-6 weeks | on quote |
| Voltage class220 kVKAL-093-04 | Voltage class: 220 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class400 kVKAL-093-05 | Voltage class: 400 kV | 1 bay · Execution 6-15 months | on quote |
Specifications
| Voltage class | 33 kV to 400 kV (see variants) |
|---|---|
| Type | Outdoor AIS |
| Scope | Civil and structuralmade to order: Erection and testing / Full turnkey |
| Transformers | Up to 315 MVA |
| Earthing | GI flat grid with ground rods |
| Bay count | 2-4 bays |
| Protection scheme | Numerical busbar protection |
| SCADA and communication | IEC 61850 compliantmade to order: IEC 60870-5-104 |
| Statutory | STU charging approvalmade to order: CEIG inspection support |
| Duration | 6-9 monthsmade to order: 12-15 months |
| Payment terms | Percentage on supply, erectionmade to order: Milestone: 10/70/10/10 |