Catalogue / Traction substations & transformers
Traction substation with circuit breakers, Flex seriesSample
by Kalinga Traction Power (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kalinga Traction Power (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Traction substation with circuit breakers from Kalinga, Flex series: 5 rating options between 10 MVA and 30 MVA. Design: withstands frequent short-circuits of traction load, condition monitoring sensors and spares and test support. Suited to metro and dedicated freight corridor, port railways and mining railways. Designed and tested to RDSO Specification, IS 2026 and IEC 60076. Lead time 16-20 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kalinga
- Model
- KAL-DE5 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 16-20 weeks
- Warranty
- 36 months from supply
- Standards
- RDSO Specification, IS 2026, IEC 60076
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating10 MVAKAL-DE5-01 | Rating: 10 MVA | 1 nos · 16-20 weeks | for verified buyers |
| Rating16 MVAKAL-DE5-02 | Rating: 16 MVA | 1 nos · 16-20 weeks | for verified buyers |
| Rating20 MVAKAL-DE5-03 | Rating: 20 MVA | 1 nos · 16-20 weeks | for verified buyers |
| Rating21.6 MVAKAL-DE5-04 | Rating: 21.6 MVA | 1 nos · 28-36 weeks | for verified buyers |
| Rating30 MVAKAL-DE5-05 | Rating: 30 MVA | 1 nos · 28-36 weeks | for verified buyers |
Specifications
| Rating | 10 MVA to 30 MVA (see variants) |
|---|---|
| Primary voltage | 110 kV |
| Secondary voltage | 2 x 27.5 kVmade to order: 27.5 kV / 55 kV (2x25) |
| Connection | Scottmade to order: Single-phase / V-V / Auto-transformer |
| Cooling | ONAN/ONAF |
| Tap changer | OLTC |
| Overload | 200% for 5 minmade to order: 150% for 15 min |
| Impedance | 8-10%made to order: 10-12% |
| Short-circuit withstand | Per RDSO |
| Insulation | Mineral oil |
| Bushings | Oil to air |
| Protection | Buchholz, OTI, WTI, PRV |
| Noise | < 75 dB(A) |