Merchants / KAMRUPEMISSIONSYST

Kamrup Emission Systems (Sample)

Kamrup Emission Systems Industries Pvt Ltd (Sample)

Verified by BARREL — PAN, GSTIN and company records checked; NDA and non-circumvention signed

Catalogue · 17 listings

Send an RFQ

Prices are shown to verified buyers. Register your company to see them and request quotes. Questions, quotes, orders and invoices all go through BARREL Shop.

SCR / SNCR NOx control

Catalyst module, Pro 3 series

SampleSCR / SNCR NOx control

Kamrup · KAM-736 series

Flue gas flow
20000 Nm3/h to 1000000 Nm3/h (see variants)
Technology
SCR
NOx removal efficiency
40%
Reagent
Ammonia 25%
Catalyst
Honeycomb V2O5-WO3/TiO2

Lead time 30-44 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price on quote

invoiced by BARREL

Request quote

SCR NOx reduction system, Xtra series

SampleSCR / SNCR NOx control

Kamrup · KAM-454 series

Flue gas flow
20000 Nm3/h to 250000 Nm3/h (see variants)
Technology
SCR
NOx removal efficiency
70%
Reagent
Ammonia 25%
Catalyst
Plate type

Lead time 16-24 weeks · Warranty 12 months from commissioning · MOQ 10 set

Price for verified buyers

invoiced by BARREL

Request quote

SNCR urea injection system, Max series

SampleSCR / SNCR NOx control

Kamrup · KAM-325 series

Flue gas flow
20000 Nm3/h to 250000 Nm3/h (see variants)
Technology
Hybrid
NOx removal efficiency
40%
Reagent
Ammonia 25%
Catalyst
Plate type

Lead time 16-24 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

ESP & bag filters

Kamrup · KAM-F04 series

Gas flow rate
250000 Am3/h to 1000000 Am3/h (see variants)
Outlet emission
Below 50 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
Polyester
Cleaning
Pulse jet

Lead time 20-28 weeks · Warranty 24 months on mechanical parts · MOQ 5 set

Price for verified buyers

invoiced by BARREL

Request quote

Kamrup · KAM-596 series

Gas flow rate
10000 Am3/h to 500000 Am3/h (see variants)
Outlet emission
Below 50 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
PPS felt
Cleaning
Pulse jet

Lead time 20-28 weeks · Warranty 24 months on mechanical parts · MOQ 1 set

Price on quote

invoiced by BARREL

Request quote

Kamrup · KAM-8F6 series

Gas flow rate
10000 Am3/h to 500000 Am3/h (see variants)
Outlet emission
Below 50 mg/Nm3
Inlet temperature
Up to 250 deg C
Filter media
PPS felt
Cleaning
Pulse jet

Lead time 20-28 weeks · Warranty 24 months on mechanical parts · MOQ 5 set

Price on quote

invoiced by BARREL

Request quote

Noise control

Kamrup · KAM-D07 series

Insertion loss
15 dB to 40 dB (see variants)
Equipment served
Fan
Panel construction
GI perforated with rockwool
Infill
Rockwool 100 mm
Sheet thickness
2.0 mm

Lead time 3-4 weeks · Warranty 24 months against corrosion · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Kamrup · KAM-004 series

Insertion loss
15 dB to 40 dB (see variants)
Equipment served
DG set
Panel construction
GI perforated with rockwool
Infill
Rockwool 50 mm
Sheet thickness
1.6 mm

Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 2 nos

Price for verified buyers

invoiced by BARREL

Request quote

Kamrup · KAM-3E4 series

Insertion loss
20 dB to 30 dB (see variants)
Equipment served
Fan
Panel construction
Double skin MS
Infill
Rockwool 50 mm
Sheet thickness
2.0 mm

Lead time 3-4 weeks · Warranty 24 months against corrosion · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Ash utilisation

Kamrup · KAM-469 series

Fly ash fineness (Blaine)
300 sq m/kg to 350 sq m/kg (see variants)
Source
ESP hopper
Grade
Siliceous Grade 2
Loss on ignition
Below 2%
Moisture
Below 1%

Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 1 MT

Price on quote

invoiced by BARREL

Request quote

Fly ash bricks, Xtra 6 series

SampleAsh utilisation

Kamrup · KAM-394 series

Fly ash fineness (Blaine)
300 sq m/kg to 400 sq m/kg (see variants)
Source
Pond ash
Grade
Siliceous Grade 1
Loss on ignition
Below 2%
Moisture
Below 5%

Lead time 3-7 days · Warranty Test certificate per lot · MOQ 5 MT

Price for verified buyers

invoiced by BARREL

Request quote

Kamrup · KAM-567 series

Fly ash fineness (Blaine)
250 sq m/kg to 400 sq m/kg (see variants)
Source
Bottom ash
Grade
Siliceous Grade 1
Loss on ignition
Below 5%
Moisture
Below 1%

Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 1 MT

Price on quote

invoiced by BARREL

Request quote

Flue-gas desulphurisation (FGD)

Seawater FGD, Elite series

SampleFlue-gas desulphurisation (FGD)

Kamrup · KAM-404 series

Boiler size
10 MW to 120 MW (see variants)
Technology
Semi-dry
SO2 removal efficiency
95%
Inlet SO2
Up to 1500 mg/Nm3
Absorber material
Alloy lined

Lead time 24-36 weeks · Warranty 24 months performance guarantee · MOQ 1 set

Price on quote

invoiced by BARREL

Request quote

Semi-dry FGD with spray dryer, Smart series

SampleFlue-gas desulphurisation (FGD)

Kamrup · KAM-059 series

Boiler size
60 MW to 500 MW (see variants)
Technology
Dry sorbent
SO2 removal efficiency
95%
Inlet SO2
Up to 1500 mg/Nm3
Absorber material
Alloy lined

Lead time 24-36 weeks · Warranty 24 months performance guarantee · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

Wet limestone FGD system, Pro 2 series

SampleFlue-gas desulphurisation (FGD)

Kamrup · KAM-776 series

Boiler size
120 MW to 500 MW (see variants)
Technology
Wet limestone-gypsum
SO2 removal efficiency
95%
Inlet SO2
Up to 2500 mg/Nm3
Absorber material
Alloy lined

Lead time 24-36 weeks · Warranty 24 months performance guarantee · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

CEMS & ambient air monitoring

Online stack gas analyser, Prime 4 series

SampleCEMS & ambient air monitoring

Kamrup · KAM-103 series

Parameters monitored
PM only to PM + gases + flow (see variants)
Measurement method
In-situ
Particulate sensor
Opacity
Gas analyser
Chemiluminescence
Data logging
4-20 mA

Lead time 10-14 weeks · Warranty 24 months on analysers · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

Ambient air quality monitoring station, Flex series

SampleCEMS & ambient air monitoring

Kamrup · KAM-6D8 series

Parameters monitored
PM only to Full CEMS 8 parameters (see variants)
Measurement method
Extractive hot-wet
Particulate sensor
Beta attenuation
Gas analyser
NDIR
Data logging
4-20 mA

Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 2 set

Price for verified buyers

invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited