Catalogue / Partial discharge & VLF testers

No photo yet

Partial discharge detector, Titan seriesSample

by Kamrupphase Test Equipment (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kamrupphase Test Equipment (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Partial discharge detector from Kamrupphase, Titan series: 6 test voltage (VLF peak) options between 28 kV and 90 kV. Key features: safety interlock and discharge rod, compact for cable testing in the field and software report with PD map. Used by cable diagnostics, MV and HV cable commissioning and switchgear PD survey. Designed and tested to IEC 60270, IEEE 400.2 and IEC 60840. Lead time 4-6 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kamrupphase
Model
KAM-D42 series
Listing type
Product
Unit
set
Minimum order
1 set
Lead time
4-6 weeks
Warranty
24 months with calibration
Standards
IEC 60270, IEEE 400.2, IEC 60840
Delivers to
North India
GST rate
18 %
Country of origin
India
Packaging
Wooden crate, seaworthy
Delivery terms
FOR nearest railhead
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Test voltage (VLF peak)28 kVKAM-D42-01Test voltage (VLF peak): 28 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)34 kVKAM-D42-02Test voltage (VLF peak): 34 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)50 kVKAM-D42-03Test voltage (VLF peak): 50 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)60 kVKAM-D42-04Test voltage (VLF peak): 60 kV1 set · 4-6 weeksfor verified buyers
Test voltage (VLF peak)80 kVKAM-D42-05Test voltage (VLF peak): 80 kV1 set · 8-14 weeksfor verified buyers
Test voltage (VLF peak)90 kVKAM-D42-06Test voltage (VLF peak): 90 kV1 set · 8-14 weeksfor verified buyers

Specifications

Test voltage (VLF peak)28 kV to 90 kV (see variants)
Test frequency0.05 Hz to 0.1 Hzmade to order: 0.1 Hz
WaveformCosine rectangular
Max load capacitance0.5 microFmade to order: 1.1 microF
PD sensitivityBelow 5 pCmade to order: Below 1 pC
PD detectionBoth
Measurement range1-10000 pC
DiagnosticsTan delta option
Power supply230 V AC
Weight85 kg
OperationTouch screen PC controlled

BARREL: Bharat Atom Renewable Resources Energy Limited