Catalogue / Testing & commissioning
Solar plant commissioning and performance ratio test, Core seriesSample
by Kaverishikhar Technical Services (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kaverishikhar Technical Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Solar plant commissioning and performance ratio test from Kaverishikhar, Core series: 3 plant capacity options between 10 MW and 50 MW. Key features: live relay setting verification, test formats agreed before mobilisation and thermography of terminations before charging. Typically used for DISCOM and STU charging, EPC handover to owners and lender completion tests. Delivered in line with IEC 62446-1, IEC 61724-1 and CEA (Technical Standards for Connectivity) Regulations. Mobilisation 1-2 weeks on site; serves South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kaverishikhar
- Model
- KAV-9A5 series
- Listing type
- Service
- Unit
- MW
- Minimum order
- 1 MW
- Lead time
- 1-2 weeks on site
- Warranty
- As per contract
- Standards
- IEC 62446-1, IEC 61724-1, CEA (Technical Standards for Connectivity) Regulations
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Plant capacity10 MWKAV-9A5-01 | Plant capacity: 10 MW | 1 MW · 1-2 weeks on site | for verified buyers |
| Plant capacity25 MWKAV-9A5-02 | Plant capacity: 25 MW | 1 MW · 1-2 weeks on site | for verified buyers |
| Plant capacity50 MWKAV-9A5-03 | Plant capacity: 50 MW | 1 MW · 1-2 weeks on site | for verified buyers |
Specifications
| Plant capacity | 10 MW to 50 MW (see variants) |
|---|---|
| Tests covered | Full plant functional and PR testmade to order: String IV curve, insulation, earth / Transformer, switchgear, relay tests |
| Instruments | Calibrated IV tracer, megger, CRMmade to order: Relay test set, thermal camera |
| Calibration | NABL traceable certificates |
| Team | Commissioning engineer plus 2 testers |
| Statutory support | CEIG inspection coordination |
| Reports | Commissioning dossier with as-builtmade to order: Test reports with signed formats |
| Duration on site | 5-7 daysmade to order: 10-14 days / 3-4 weeks |
| Performance guarantee test | 72-hour trial runmade to order: Capacity and PR test per contract |
| Grid code checks | Not included |
| Payment | 50% on start, 50% on reportmade to order: Milestone on energisation |