Catalogue / Substation & line O&M

No photo yet

Transmission line patrolling and maintenance, Prime 8 seriesSample

by Kutch Engineering Services (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kutch Engineering Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Kutch Prime 8 transmission line patrolling and maintenance, offered in 4 voltage level options from 11 kV to 132 kV. Key features: insulator and joint inspection, fault analysis within 24 hours and outage planning with the utility. Typically used for state utility outsourcing, industrial captive substations and railway and metro sub-stations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kutch
Model
KUT-729 series
Listing type
Service
Unit
month
Minimum order
1 month
Lead time
Baseline condition audit first
Warranty
As per contract
Standards
CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Voltage level11 kVKUT-729-01Voltage level: 11 kV1 month · Baseline condition audit firston quote
Voltage level33 kVKUT-729-02Voltage level: 33 kV1 month · Baseline condition audit firston quote
Voltage level66 kVKUT-729-03Voltage level: 66 kV1 month · Baseline condition audit firston quote
Voltage level132 kVKUT-729-04Voltage level: 132 kV1 month · Baseline condition audit firston quote

Specifications

Voltage level11 kV to 132 kV (see variants)
ScopeOperation, maintenance and statutory compliancemade to order: Operation and maintenance / Maintenance only
Shift patternGeneral shift plus on-callmade to order: 3 shifts, 24x7
ManpowerEngineer plus 6 operatorsmade to order: Two engineers plus 12 staff
Line patrollingMonthly foot patrolmade to order: Quarterly drone patrol
TestingAnnual relay and CT/PT test
Statutory recordsCEIG renewal supportmade to order: Log books, permits, shutdown register
SparesConsumables includedmade to order: Critical spares by owner
Response time2 hours for tripmade to order: 4 hours
ReportingMonthly fault and maintenance report
Term3 yearsmade to order: 1 year

BARREL: Bharat Atom Renewable Resources Energy Limited