Catalogue / Substation & line O&M

No photo yet

Power transformer routine checks, Titan seriesSample

by Kutch Engineering Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kutch Engineering Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Power transformer routine checks from Kutch, Titan series: 4 voltage level options between 66 kV and 400 kV. Design: outage planning with the utility, fault analysis within 24 hours and permit-to-work and lockout-tagout. Suited to renewable pooling substations, state utility outsourcing and railway and metro sub-stations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kutch
Model
KUT-056 series
Listing type
Service
Unit
month
Minimum order
1 month
Lead time
Baseline condition audit first
Warranty
As per contract
Standards
CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Voltage level66 kVKUT-056-01Voltage level: 66 kV1 month · Baseline condition audit firstfor verified buyers
Voltage level132 kVKUT-056-02Voltage level: 132 kV1 month · Baseline condition audit firstfor verified buyers
Voltage level220 kVKUT-056-03Voltage level: 220 kV1 month · Baseline condition audit firstfor verified buyers
Voltage level400 kVKUT-056-04Voltage level: 400 kV1 month · Baseline condition audit firstfor verified buyers

Specifications

Voltage level66 kV to 400 kV (see variants)
ScopeOperation and maintenance
Shift patternGeneral shift plus on-call
ManpowerEngineer plus 6 operators
Line patrollingQuarterly drone patrol
TestingAnnual relay and CT/PT test
Statutory recordsCEIG renewal supportmade to order: Log books, permits, shutdown register
SparesCritical spares by owner
Response time4 hoursmade to order: 2 hours for trip
ReportingReal-time dashboards
Term1 yearmade to order: 3 years

BARREL: Bharat Atom Renewable Resources Energy Limited