Prithvimax Elite 9 clean-air insulated breaker, offered in 5 system voltage options from 36 kV to 245 kV. Key features: same footprint as SF6 designs, lower maintenance and disposal cost and vacuum interrupter lasts life of the unit. Suited to industrial campuses, ESG-driven developers and green substations. Designed and tested to IEC 62271-100, IEC 62271-1 and IS 13118. Lead time 16-20 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Prithvimax
- Model
- PRI-2A5 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 16-20 weeks
- Warranty
- 24 months
- Standards
- IEC 62271-100, IEC 62271-1, IS 13118
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVPRI-2A5-01 | System voltage: 36 kV | 1 nos · 16-20 weeks | on quote |
| System voltage72.5 kVPRI-2A5-02 | System voltage: 72.5 kV | 1 nos · 16-20 weeks | on quote |
| System voltage145 kVPRI-2A5-03 | System voltage: 145 kV | 1 nos · 16-20 weeks | on quote |
| System voltage170 kVPRI-2A5-04 | System voltage: 170 kV | 1 nos · 30-40 weeks | on quote |
| System voltage245 kVPRI-2A5-05 | System voltage: 245 kV | 1 nos · 30-40 weeks | on quote |
Specifications
| System voltage | 36 kV to 245 kV (see variants) |
|---|---|
| Insulation medium | Fluoronitrile mix |
| Interrupter | Multi-break vacuum |
| Rated current | 3150 A |
| Breaking current | 31.5 kA |
| Mechanism | Spring |
| Global warming potential | < 1 |
| Mechanical life | 10000 operations |
| Gas handling | No SF6 handling |
| Temperature range | -25 to 50 deg C |
| Housing | Compositemade to order: Porcelain |
| Control voltage | 110 V DC |
| Monitoring | Pressure sensor |