SF6-free (vacuum, clean-air) HV breakers

Sub-category C06-07 of HV & EHV switchgear.

Companies offering this · 20

Listings (32)

Prices are shown to verified buyers. Register your company to see them and request quotes.

Clean-air insulated breaker, Elite 9 series

SampleSF6-free (vacuum, clean-air) HV breakers

Prithvimax · PRI-2A5 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Multi-break vacuum
Rated current
3150 A
Breaking current
31.5 kA

Lead time 16-20 weeks · Warranty 24 months · MOQ 1 nos

Price on quote

by Prithvimax HV Switchgear (Sample) · invoiced by BARREL

Request quote

g3-gas insulated bay, Prime series

SampleSF6-free (vacuum, clean-air) HV breakers

Konkanparam · KON-528 series

System voltage
36 kV to 170 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Multi-break vacuum
Rated current
3150 A
Breaking current
40 kA

Lead time 16-20 weeks · Warranty 36 months · MOQ 1 nos

Price for verified buyers

by Konkanparam Switchgear (Sample) · invoiced by BARREL

Request quote

Clean-air insulated breaker, Neo series

SampleSF6-free (vacuum, clean-air) HV breakers

Sahyadri · SAH-2A3 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Dry air
Interrupter
Vacuum
Rated current
2000 A
Breaking current
25 kA

Lead time 16-20 weeks · Warranty 36 months · MOQ 5 nos

Price on quote

by Sahyadri HV Switchgear (Sample) · invoiced by BARREL

Request quote

Vacuum technology HV breaker, Pro series

SampleSF6-free (vacuum, clean-air) HV breakers

Ujjayini · UJJ-1E1 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Dry air
Interrupter
Vacuum
Rated current
2000 A
Breaking current
25 kA

Lead time 30-40 weeks · Warranty 36 months · MOQ 1 nos

Price on quote

by Ujjayini Switchgear (Sample) · invoiced by BARREL

Request quote

Vacuum technology HV breaker, Smart series

SampleSF6-free (vacuum, clean-air) HV breakers

Sabarmati · SAB-1E2 series

System voltage
36 kV to 170 kV (see variants)
Insulation medium
Dry air
Interrupter
Multi-break vacuum
Rated current
2000 A
Breaking current
40 kA

Lead time 16-20 weeks · Warranty 24 months · MOQ 1 nos

Price on quote

by Sabarmati Grid Switchgear (Sample) · invoiced by BARREL

Request quote

Vacuum technology HV breaker, Volt series

SampleSF6-free (vacuum, clean-air) HV breakers

Amaravatianant · AMA-1E6 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Clean air
Interrupter
Vacuum
Rated current
3150 A
Breaking current
25 kA

Lead time 30-40 weeks · Warranty 36 months · MOQ 10 nos

Price for verified buyers

by Amaravatianant Switchgear (Sample) · invoiced by BARREL

Request quote

SF6-free live tank breaker, Smart 2 series

SampleSF6-free (vacuum, clean-air) HV breakers

Jhelum · JHE-CC2 series

System voltage
36 kV to 145 kV (see variants)
Insulation medium
Dry air
Interrupter
Multi-break vacuum
Rated current
3150 A
Breaking current
25 kA

Lead time 30-40 weeks · Warranty 24 months · MOQ 1 nos

Price for verified buyers

by Jhelum Switchgear (Sample) · invoiced by BARREL

Request quote

SF6-free live tank breaker, Core series

SampleSF6-free (vacuum, clean-air) HV breakers

Mewar · MEW-CC6 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Dry air
Interrupter
Vacuum
Rated current
1250 A
Breaking current
25 kA

Lead time 30-40 weeks · Warranty 36 months · MOQ 1 nos

Price for verified buyers

by Mewar Grid Switchgear (Sample) · invoiced by BARREL

Request quote

g3-gas insulated bay, Neo series

SampleSF6-free (vacuum, clean-air) HV breakers

Coromandelphase · COR-524 series

System voltage
36 kV to 170 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Vacuum
Rated current
2000 A
Breaking current
31.5 kA

Lead time 16-20 weeks · Warranty 24 months · MOQ 5 nos

Price for verified buyers

by Coromandelphase Switchgear (Sample) · invoiced by BARREL

Request quote

Vacuum technology HV breaker, Duo 4 series

SampleSF6-free (vacuum, clean-air) HV breakers

Jhelumtesla · JHE-1E4 series

System voltage
36 kV to 170 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Vacuum
Rated current
1250 A
Breaking current
40 kA

Lead time 16-20 weeks · Warranty 36 months · MOQ 1 nos

Price for verified buyers

by Jhelumtesla HV Switchgear (Sample) · invoiced by BARREL

Request quote

Clean-air insulated breaker, Elite series

SampleSF6-free (vacuum, clean-air) HV breakers

Prithvicore · PRI-2A2 series

System voltage
145 kV to 245 kV (see variants)
Insulation medium
Clean air
Interrupter
Vacuum
Rated current
1250 A
Breaking current
31.5 kA

Lead time 30-40 weeks · Warranty 36 months · MOQ 5 nos

Price for verified buyers

by Prithvicore Grid Switchgear (Sample) · invoiced by BARREL

Request quote

Clean-air insulated breaker, Max series

SampleSF6-free (vacuum, clean-air) HV breakers

Prithvicore · PRI-2A8 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Clean air
Interrupter
Multi-break vacuum
Rated current
1250 A
Breaking current
31.5 kA

Lead time 16-20 weeks · Warranty 24 months · MOQ 1 nos

Price for verified buyers

by Prithvicore Grid Switchgear (Sample) · invoiced by BARREL

Request quote

g3-gas insulated bay, Ultra 7 series

SampleSF6-free (vacuum, clean-air) HV breakers

Konkanparam · KON-528 series

System voltage
145 kV to 245 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Multi-break vacuum
Rated current
3150 A
Breaking current
31.5 kA

Lead time 30-40 weeks · Warranty 24 months · MOQ 2 nos

Price for verified buyers

by Konkanparam Switchgear (Sample) · invoiced by BARREL

Request quote

Clean-air insulated breaker, Pro series

SampleSF6-free (vacuum, clean-air) HV breakers

Prithvimax · PRI-2A6 series

System voltage
36 kV to 170 kV (see variants)
Insulation medium
Clean air
Interrupter
Multi-break vacuum
Rated current
2000 A
Breaking current
25 kA

Lead time 16-20 weeks · Warranty 24 months · MOQ 1 nos

Price for verified buyers

by Prithvimax HV Switchgear (Sample) · invoiced by BARREL

Request quote

Vacuum technology HV breaker, Eco series

SampleSF6-free (vacuum, clean-air) HV breakers

Jhelumtesla · JHE-1E2 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Clean air
Interrupter
Multi-break vacuum
Rated current
1250 A
Breaking current
25 kA

Lead time 30-40 weeks · Warranty 24 months · MOQ 2 nos

Price for verified buyers

by Jhelumtesla HV Switchgear (Sample) · invoiced by BARREL

Request quote

Clean-air insulated breaker, Plus series

SampleSF6-free (vacuum, clean-air) HV breakers

Sahyadri · SAH-2A1 series

System voltage
145 kV to 245 kV (see variants)
Insulation medium
Clean air
Interrupter
Multi-break vacuum
Rated current
1250 A
Breaking current
31.5 kA

Lead time 16-20 weeks · Warranty 36 months · MOQ 10 nos

Price for verified buyers

by Sahyadri HV Switchgear (Sample) · invoiced by BARREL

Request quote

Clean-air insulated breaker, Duo 5 series

SampleSF6-free (vacuum, clean-air) HV breakers

Sahyadritamra · SAH-2A7 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Clean air
Interrupter
Vacuum
Rated current
2000 A
Breaking current
31.5 kA

Lead time 30-40 weeks · Warranty 24 months · MOQ 5 nos

Price on quote

by Sahyadritamra HV Switchgear (Sample) · invoiced by BARREL

Request quote

Vacuum technology HV breaker, Eco 3 series

SampleSF6-free (vacuum, clean-air) HV breakers

Sabarmati · SAB-1E1 series

System voltage
145 kV to 245 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Vacuum
Rated current
2000 A
Breaking current
31.5 kA

Lead time 16-20 weeks · Warranty 36 months · MOQ 1 nos

Price for verified buyers

by Sabarmati Grid Switchgear (Sample) · invoiced by BARREL

Request quote

SF6-free live tank breaker, Smart series

SampleSF6-free (vacuum, clean-air) HV breakers

Rajatline · RAJ-CC5 series

System voltage
36 kV to 245 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Vacuum
Rated current
1250 A
Breaking current
25 kA

Lead time 16-20 weeks · Warranty 24 months · MOQ 1 nos

Price for verified buyers

by Rajatline HV Switchgear (Sample) · invoiced by BARREL

Request quote

SF6-free live tank breaker, Core 5 series

SampleSF6-free (vacuum, clean-air) HV breakers

Mewar · MEW-CC5 series

System voltage
72.5 kV to 245 kV (see variants)
Insulation medium
Fluoronitrile mix
Interrupter
Multi-break vacuum
Rated current
2000 A
Breaking current
40 kA

Lead time 30-40 weeks · Warranty 24 months · MOQ 10 nos

Price for verified buyers

by Mewar Grid Switchgear (Sample) · invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited