Catalogue / Waste-heat recovery units

No photo yet

Waste-heat to power steam turbine set, Max seriesSample

by Ravi Gas Power Systems (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Ravi Gas Power Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Ravi Max waste-heat to power steam turbine set, offered in 6 recovered heat options from 0.5 MWth to 20 MWth. Highlights: corrosion protection for low-temperature end, diverter damper for independent engine operation and increase total plant efficiency to 80 percent plus. Typically used for process heat users, gas engine plants and CHP plants. Designed and tested to IBR 1950, ASME Sec VIII and IS 2825. Lead time 18-26 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Ravi
Model
RAV-B14 series
Listing type
Product
Unit
nos
Minimum order
5 nos
Lead time
18-26 weeks
Warranty
12 months
Standards
IBR 1950, ASME Sec VIII, IS 2825
Delivers to
West India
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
FOR nearest railhead
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Recovered heat0.5 MWthRAV-B14-01Recovered heat: 0.5 MWth5 nos · 18-26 weekson quote
Recovered heat1 MWthRAV-B14-02Recovered heat: 1 MWth5 nos · 18-26 weekson quote
Recovered heat3 MWthRAV-B14-03Recovered heat: 3 MWth5 nos · 18-26 weekson quote
Recovered heat5 MWthRAV-B14-04Recovered heat: 5 MWth5 nos · 18-26 weekson quote
Recovered heat10 MWthRAV-B14-05Recovered heat: 10 MWth5 nos · 18-26 weekson quote
Recovered heat20 MWthRAV-B14-06Recovered heat: 20 MWth5 nos · 18-26 weekson quote

Specifications

Recovered heat0.5 MWth to 20 MWth (see variants)
Heat sourceGas turbine exhaust
Gas inlet temperature650 C
MediumOrganic fluidmade to order: Steam / Hot water / Thermal oil
Steam pressure8 bar
Power output (ORC)2 MWmade to order: 100 kW / 500 kW
ConstructionBare tube
MaterialCarbon steelmade to order: Corten / SS 304
Bypass damperDiverter included
Design codeASME
Gas pressure drop< 250 mmWC

BARREL: Bharat Atom Renewable Resources Energy Limited