Waste-heat recovery unitsBundel5 variants
SampleWaste-heat recovery units Bundel · BUN-673 series
- Recovered heat
- 0.5 MWth to 10 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 400 C
- Medium
- Thermal oil
- Steam pressure
- 8 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 10 nos
Waste-heat recovery unitsMahabaleshwarprakash6 variants
SampleWaste-heat recovery units Mahabaleshwarprakash · MAH-604 series
- Recovered heat
- 0.5 MWth to 20 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 550 C
- Medium
- Steam
- Steam pressure
- 40 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 1 nos
Waste-heat recovery unitsGupta5 variants
SampleWaste-heat recovery units Gupta · GUP-FE1 series
- Recovered heat
- 0.5 MWth to 10 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Hot water
- Steam pressure
- 8 bar
Lead time 18-26 weeks · Warranty 18 months · MOQ 1 nos
Waste-heat recovery unitsIndraprasthaflux6 variants
SampleWaste-heat recovery units Indraprasthaflux · IND-602 series
- Recovered heat
- 0.5 MWth to 20 MWth (see variants)
- Heat source
- Gas turbine exhaust
- Gas inlet temperature
- 400 C
- Medium
- Thermal oil
- Steam pressure
- 17 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 1 nos
Waste-heat recovery unitsLonavalavajra4 variants
SampleWaste-heat recovery units Lonavalavajra · LON-678 series
- Recovered heat
- 3 MWth to 20 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 550 C
- Medium
- Thermal oil
- Steam pressure
- 40 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 2 nos
Waste-heat recovery unitsLonavalavajra4 variants
SampleWaste-heat recovery units Lonavalavajra · LON-FE3 series
- Recovered heat
- 1 MWth to 10 MWth (see variants)
- Heat source
- Gas turbine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Steam
- Steam pressure
- 8 bar
Lead time 18-26 weeks · Warranty 18 months · MOQ 10 nos
Waste-heat recovery unitsVaigaispark3 variants
SampleWaste-heat recovery units Vaigaispark · VAI-FE1 series
- Recovered heat
- 5 MWth to 20 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 650 C
- Medium
- Organic fluid
- Steam pressure
- 40 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 1 nos
Waste-heat recovery unitsSatavahana5 variants
SampleWaste-heat recovery units Satavahana · SAT-679 series
- Recovered heat
- 1 MWth to 20 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 400 C
- Medium
- Thermal oil
- Steam pressure
- 40 bar
Lead time 18-26 weeks · Warranty 12 months · MOQ 1 nos
Waste-heat recovery unitsIndraprasthaflux3 variants
SampleWaste-heat recovery units Indraprasthaflux · IND-B17 series
- Recovered heat
- 0.5 MWth to 3 MWth (see variants)
- Heat source
- Gas turbine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Hot water
- Steam pressure
- 8 bar
Lead time 18-26 weeks · Warranty 12 months · MOQ 2 nos
Waste-heat recovery unitsLonavalavajra4 variants
SampleWaste-heat recovery units Lonavalavajra · LON-1E2 series
- Recovered heat
- 1 MWth to 10 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 400 C
- Medium
- Steam
- Steam pressure
- 17 bar
Lead time 18-26 weeks · Warranty 12 months · MOQ 2 nos
Waste-heat recovery unitsVaigaispark3 variants
SampleWaste-heat recovery units Vaigaispark · VAI-1E1 series
- Recovered heat
- 0.5 MWth to 3 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 400 C
- Medium
- Thermal oil
- Steam pressure
- 40 bar
Lead time 18-26 weeks · Warranty 12 months · MOQ 2 nos
Waste-heat recovery unitsGupta3 variants
SampleWaste-heat recovery units Gupta · GUP-B18 series
- Recovered heat
- 5 MWth to 20 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 400 C
- Medium
- Thermal oil
- Steam pressure
- 17 bar
Lead time 10-14 weeks · Warranty 18 months · MOQ 1 nos
Waste-heat recovery unitsIndraprasthaflux3 variants
SampleWaste-heat recovery units Indraprasthaflux · IND-1E2 series
- Recovered heat
- 5 MWth to 20 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 550 C
- Medium
- Thermal oil
- Steam pressure
- 17 bar
Lead time 18-26 weeks · Warranty 18 months · MOQ 10 nos
Waste-heat recovery unitsRavi6 variants
SampleWaste-heat recovery units Ravi · RAV-B14 series
- Recovered heat
- 0.5 MWth to 20 MWth (see variants)
- Heat source
- Gas turbine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Organic fluid
- Steam pressure
- 8 bar
Lead time 18-26 weeks · Warranty 12 months · MOQ 5 nos
Waste-heat recovery unitsVaigaispark4 variants
SampleWaste-heat recovery units Vaigaispark · VAI-672 series
- Recovered heat
- 1 MWth to 10 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 550 C
- Medium
- Hot water
- Steam pressure
- 40 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 10 nos
Waste-heat recovery unitsAwadh4 variants
SampleWaste-heat recovery units Awadh · AWA-B11 series
- Recovered heat
- 1 MWth to 10 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 550 C
- Medium
- Organic fluid
- Steam pressure
- 40 bar
Lead time 10-14 weeks · Warranty 18 months · MOQ 5 nos
Waste-heat recovery unitsLohacore3 variants
SampleWaste-heat recovery units Lohacore · LOH-B18 series
- Recovered heat
- 1 MWth to 5 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 550 C
- Medium
- Organic fluid
- Steam pressure
- 40 bar
Lead time 18-26 weeks · Warranty 12 months · MOQ 5 nos
Waste-heat recovery unitsLohacore6 variants
SampleWaste-heat recovery units Lohacore · LOH-675 series
- Recovered heat
- 0.5 MWth to 20 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Organic fluid
- Steam pressure
- 17 bar
Lead time 18-26 weeks · Warranty 18 months · MOQ 10 nos
Waste-heat recovery unitsLohacore4 variants
SampleWaste-heat recovery units Lohacore · LOH-FE1 series
- Recovered heat
- 3 MWth to 20 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Organic fluid
- Steam pressure
- 8 bar
Lead time 10-14 weeks · Warranty 18 months · MOQ 1 nos
Waste-heat recovery unitsAwadh5 variants
SampleWaste-heat recovery units Awadh · AWA-FE6 series
- Recovered heat
- 0.5 MWth to 10 MWth (see variants)
- Heat source
- Gas engine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Thermal oil
- Steam pressure
- 17 bar
Lead time 18-26 weeks · Warranty 12 months · MOQ 1 nos
Waste-heat recovery unitsAwadh6 variants
SampleWaste-heat recovery units Awadh · AWA-601 series
- Recovered heat
- 0.5 MWth to 20 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 400 C
- Medium
- Organic fluid
- Steam pressure
- 8 bar
Lead time 10-14 weeks · Warranty 18 months · MOQ 5 nos
Waste-heat recovery unitsRavi5 variants
SampleWaste-heat recovery units Ravi · RAV-FE4 series
- Recovered heat
- 1 MWth to 20 MWth (see variants)
- Heat source
- Gas turbine exhaust
- Gas inlet temperature
- 400 C
- Medium
- Thermal oil
- Steam pressure
- 17 bar
Lead time 18-26 weeks · Warranty 18 months · MOQ 1 nos
Waste-heat recovery unitsMahabaleshwarprakash3 variants
SampleWaste-heat recovery units Mahabaleshwarprakash · MAH-672 series
- Recovered heat
- 0.5 MWth to 3 MWth (see variants)
- Heat source
- Kiln gas
- Gas inlet temperature
- 400 C
- Medium
- Thermal oil
- Steam pressure
- 17 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 1 nos
Waste-heat recovery unitsSatavahana4 variants
SampleWaste-heat recovery units Satavahana · SAT-B16 series
- Recovered heat
- 0.5 MWth to 5 MWth (see variants)
- Heat source
- Gas turbine exhaust
- Gas inlet temperature
- 650 C
- Medium
- Hot water
- Steam pressure
- 8 bar
Lead time 10-14 weeks · Warranty 12 months · MOQ 10 nos