Catalogue / Power system studies (load flow, short circuit, grid code)

No photo yet

Load flow and short-circuit study, Duo seriesSample

by Vidyutline Technical Services (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vidyutline Technical Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Vidyutline Duo load flow and short-circuit study, offered in 6 network scale options from 11 kV plant to 400 kV system. Design: relay setting files ready to load, reactive power capability curves and PSS/E and PSCAD model support. Suited to industrial plants adding generation, BESS integrators and renewable developers seeking connectivity. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation 2-6 weeks; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vidyutline
Model
VID-465 series
Listing type
Service
Unit
report
Minimum order
1 report
Lead time
2-6 weeks
Warranty
Revision for utility comments
Standards
CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Network scale11 kV plantVID-465-01Network scale: 11 kV plant1 report · 2-6 weekson quote
Network scale33 kV plantVID-465-02Network scale: 33 kV plant1 report · 2-6 weekson quote
Network scale66 kV systemVID-465-03Network scale: 66 kV system1 report · 2-6 weekson quote
Network scale132 kV systemVID-465-04Network scale: 132 kV system1 report · 2-6 weekson quote
Network scale220 kV systemVID-465-05Network scale: 220 kV system1 report · 2-6 weekson quote
Network scale400 kV systemVID-465-06Network scale: 400 kV system1 report · 2-6 weekson quote

Specifications

Network scale11 kV plant to 400 kV system (see variants)
Study typeHarmonicsmade to order: Load flow and short circuit / Dynamic and transient / Protection coordination
SoftwareDIgSILENT PowerFactorymade to order: ETAP / PSS/E
Model dataClient single line diagram and data
DeliverablesModel files and relay settingsmade to order: Study report with results
Grid code checksVoltage and reactive power capabilitymade to order: LVRT/HVRT and ramp rate
ReviewLender reviewmade to order: Utility submission support
ScenariosMultiple dispatch cases
TeamLead plus modelling specialistmade to order: Power system engineer
Turnaround2-3 weeks
ValidationCompared with measured data

BARREL: Bharat Atom Renewable Resources Energy Limited